| 2011-11-03 15:26:22 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW CHECKLIST. |
| | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| | |
| | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| | COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE |
| | DUE. BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID |
| | RECEIPT IF FEES ARE DUE. . |
| | |
| | 2- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 |
| | FLORIDA STATUTES. |
| | |
| | 3- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW. |
| | VALUATION WAS UPDATED AS REQUIRED BY SEC. 108.3 CITY |
| | AMENDMENTS TO FBC. PERMIT FEE BALANCE DUE IS $539.30. |
| | |
| | 4- SHEET 1 OF 3: |
| | A) SPECIFY SAFETY GLASS ON DINING RM WINDOW ADJACENT TO |
| | THE DOOR AND NEW BATHROOM WINDOW. SEC. R308.4. |
| | |
| | B) UPDATE/REVISE DESIGN PARAMETER TABLE: *SPECIFY THE |
| | FBC 2007 WITH 2009 REVISIONS. **REFERENCE ASCE 7-05 NOT |
| | ASCE 7-02. ***SPECIFY THE MEAN ROOF HEIGHT. ****SPECIFY |
| | THE FLAT ROOF SLOPE. |
| | SEC. 106.1.1 CITY AMENDMENTS TO FBC. |
| | |
| | 5- SHEET 2 OF 3: UPDATE THE FLORIDA PRODUCT APPROVAL |
| | NUMBERS SHOWN ON THE TRUSS ANCHOR SCHEDULE. NEED |
| | NUMBERS FOR 2007 CODE VERSION. VISIT WEBSITE AND REVISE |
| | AS REQUIRED. AND SPECIFY THE FLORIDA PRODUCT APPROVAL |
| | FOR ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON THE |
| | WALL SECTIONS ON SHEET 3 OF 3. |
| | |
| | 6- SHEET 3 OF 3: A) WALL SECTION "A": CLARIFY WHY ROOF |
| | INSULATION R-VALUE IS R-1? |
| | |
| | B) SPECIFY 7/8" STUCCO THICKNESS AS REQUIRED BY TABLE |
| | R702.1(1). THIS APPLIES TO ALL WALL SECTIONS SHOWN ON |
| | THIS SHEET. |
| | |
| | C) CLARIFY SIZE OF ANCHOR BOLT SPECIFIED FOR THE WALL |
| | BOTTOM PLATE. IS IT 1/2" OR 5/8"?. WALL SECTIONS A AND |
| | B CALLS FOR 5/8" WHILE WALL SECTION C CALLS FOR 1/2". |
| | |
| | D) WALL SECTION "B". SPECIFY THE R-VALUE OF ROOF |
| | INSULATION. SEE ENERGY CALCULATIONS. |
| | |
| | E) WALL SECTION C-C: SPECIFY CONTINUOUS ROOF VENT TO |
| | COMPLY WITH THE CROSS VENTILATION OF SEC. R806. |
| | |
| | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) WINDOW MULLIONS AS SHOWN ON PLANS. |
| | |
| | B) SINGLE HUNG WINDOWS. NOA 06-0706.03 SUBMITTED |
| | EXPIRED ON OCTOBER 08, 2011. |
| | |
| | 8- PROVIDE COMPLETE INSTALLATION SCHEDULE FOR THE |
| | INSTALLATION OF THE STORM PANELS AS REQUIRED BY CITY |
| | HURRICANE IMPACT PROTECTION POLICY. |
| | |
| | 9- FLAT ROOF NOA 09-0224.01 SUBMITTED: A) SPECIFY WHICH |
| | APPROVED ASSEMBLY IS GOING TO BE INSTALLED. |
| | |
| | B) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR |
| | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS |
| | REQUIRED BY GENERAL LIMITATION #7 TO MEET THE DESIGN |
| | PRESSURES REQUIRED BY SEC. R301.2.1.4.3. |
| | |
| | 10- ENERGY CALCULATIONS SUBMITTED: |
| | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM |
| | INCLUDING OWNER'S NAME AND REVISE THE JURISDICTION |
| | NUMBER. THIS JURISDICTION NUMBER IS 604700 NOT 601000. |
| | |
| | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM ALSO. |
| | |
| | C) REVISE THE WINDOWS INSTALLED VALUE. ON TABLE 11B-1 |
| | ON SHEET #2. THE U-FACTOR AND SHGC FACTOR NEED TO BE |
| | EQUAL OR BETTER THAN THE ONE SHOWN ON THE PERFORMANCE |
| | CRITERIA COLUMN. THE LOWER THE NUMBER THE BETTER THE |
| | PERFORMANCE. VALUES SHOWN ON THE INSTALLED COLUMN ARE |
| | HIGHER, THEREFORE MAKING IT WORST THAN THE REQUIRED |
| | PERFORMANCE CRITERIA. REVISE AS REQUIRED. |
| | |
| | D) REVISE THE CHECK (NA) ON THE LAST TWO ITEMS OF TABLE |
| | 11B-2. COORDINATE WITH ITEM #11 BELOW. |
| | |
| | 11- NEED TO SPECIFY HOW PROVIDING HEATING TO THE NEW |
| | STUDY LIVABLE SPACE AS REQUIRED BY SEC. R303.8. |
| | NOTE: PORTABLE HEATERS ARE NOT ALLOWED. |
| | |
| | 12- PROVIDE COMPLETE OPENING FRAMING DETAILS FOR NEW |
| | DOORS AND WINDOWS. DRAWINGS ON SHEET 3 OF 3 ARE MISSING |
| | THE JAMBS INFORMATION AND SPECIFY ALL FASTENERS. SEC. |
| | 106.1.1 CITY AMENDMENTS TO FBC. |
| | |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |