| Plan Review Notes For Permit 11100276 |
| Permit Number |
11100276 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-10-14 09:38:35 | 2007 FBC W/2009 REVISIONS | | | | | | 1) THE PLANS THAT WERE SUBMITTED HAVE AN ARCHITECT'S | | | TITLE BLOCK BUT HAVE NOT BE SIGNED AND SEALED AS | | | REQUIRED BY FS 481 AND FAC 61G-16.004. | | | | | | 2) THE DRAWINGS THAT WERE SUBMITTED DO NOT SPECIFY ANY | | | REINFORCING STEEL IN THE CONCRETE FOOTINGS. FBC R401.2 | | | , R403.1 AND R404.1 PLEASE CLARIFY. | | | | | | 3) SHOW COMPLIANCE WITH FBC R320.1.6 WHICH REQUIRES | | | SOIL TREATMENT FOR TERMITES UNDER ALL EXTERIOR CONCRETE | | | OR GRADE WITHIN 1 FOOT OFF THE PRIMARY STRUCTURE | | | SIDEWALLS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|