2011-10-19 15:28:5011100165
 2416 MEDINA WAY
 INTERIOR RESIDENTIAL RENOVATION
  
 VERIFY THE EXISTING LIVING ROOM BEING RENOVATED HAS
 RECEPTACLES PROPERLY SPACED. NEC 210.52
 VERIFY OR PROVIDE SMOKE DETECTORS AND CARBON MONOXIDE
 DETECTORS AS REQUIRED FOR ADDITIONS AND RENOVATIONS.
 FBC R 313.2.1, R313.4
 VERIFY THAT COUNTER TOP RECEPTACLES ARE GFCI PROTECTED
 AND DISTRIBUTED APPROPRIATELY. NEC 210.8, 210.52
 VERIFY OR PROVIDE A GFCI PROTECTED RECEPTACLE ON THE
 NEW TERRACE. NEC 210.8
 PROVIDE SPECIFICATIONS ON THE TERRACE CEILING FANS
 INDICATING THE EQUIPMENT IS SUITABLE FOR USE IN A DAMP
 LOCATION. NEC 110.11
  
  