Plan Review Notes
Plan Review Notes For Permit 11100141
Permit Number 11100141
Review Stop B
Sequence Number 2
Notes
Date Text
2011-11-28 14:52:22BUILDING PLAN REVIEW
 PERMIT: 11100141
 ADD: 4275 45TH ST
 CONT: TO BE DETERMINED
 TEL: (561)743-8066
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW PLEASE SEE FIRST REVIEW NO NEW COMMENTS> JW
 ACTION: DENIED
  
 1) SHEET S2 INDICATES A "B" EXPOSURE AND ASSOCIATED
 PRESSURES, FBC-B 1609.4.3 PLEASE SEE THIS EXPOSURE
 SHALL ALSO APPLY TO ANY BUILDING LOCATED WITHIN
 EXPOSURE B-TYPE TERRAIN WHERE THE BUILDING IS WITHIN
 100 FEET HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF
 EXPOSURE C-TYPE TERRAIN THAT EXTENDS MORE THAN 600 FEET
 (182.9 M) AND WIDTH GREATER THAN 150 FT. IN THE UPWIND
 DIRECTION.
  
 PRESSURES ARE LOW FOR "C" TYPE TERRAIN.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  