2011-10-07 16:15:07****PROVISO****
 604.9 WATER HAMMER. THE FLOW VELOCITY OF THE WATER
 DISTRIBUTION SYSTEM SHALL BE CONTROLLED TO REDUCE THE
 POSSIBILITY OF WATER HAMMER. A WATER-HAMMER ARRESTOR
 SHALL BE INSTALLED WHERE QUICK-CLOSING VALVES ARE
 UTILIZED. WATER-HAMMER ARRESTORS SHALL BE INSTALLED IN
 ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
 WATER-HAMMER ARRESTORS SHALL CONFORM TO ASSE 1010.
  
 ****NOTE****
 NOT INCLUDED IN THIS REVIEW :
 GREASE TRAP
 IRRIGATION
 FUEL GAS
 SEPARATE APPLICATION, DRAWING, AND PERMIT REQUIRED
  