| 2011-10-12 16:46:14 | NSF RESIDENCE (R3) BUILDING REVIEW CHECKLIST. |
| | 2007 FLORIDA RESIDENTIAL CODE W/ 2009 REVISIONS. |
| | |
| | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO |
| | PAY IMPACT FEES. BRING BACK STAMPED PLANS AND COPY OF |
| | PAID RECEIPT. |
| | |
| | 2- VALUED DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. IT WAS UPDATED AS REQUIRED BY SEC. 108.3 CITY |
| | AMENDMENTS TO FBC. REVISED PERMIT FEE BALANCE IS |
| | $6550.58. |
| | |
| | 3- SOIL TEST REPORT SUBMITTED NEEDS TO HAVE THE |
| | ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY |
| | CHAPTER 471 FLORIDA STATUTE. |
| | |
| | 4- PROVIDE LOT DRAINAGE PLAN. SEC. R401.3. |
| | |
| | 5- SHEET S-2: |
| | A) SPECIFY ALL LOADS AS REQUIRED BY SEC. R301.1 AND |
| | TABLE R301.5. INCLUDE ALL ATTIC LIVE LOADS REQUIRED BY |
| | TABLE R301.5 AND FOOTNOTES B, G, AND H. COORDINATE WITH |
| | ITEM #5D BELOW. |
| | |
| | B) REVISE CASCRETE UPLIFT CALCULATIONS. NEED TO USE |
| | EXPOSURE "C" NOT "B". |
| | |
| | C) REVISE TRUSS DESIGN CRITERIA. USE ASCE 7-05 |
| | REFERENCE NOT ASCE 7-02. |
| | |
| | D) SPECIFY THE 30PSF LIVE LOAD ON THE TRUSS LOADS AS |
| | SPECIFIED ON NOTE #7 OF THE TRUSS DESIGN CRITERIA |
| | TABLE. |
| | ***NOTE: TRUSS DRAWINGS NEED TO BE REVISED ACCORDINGLY. |
| | |
| | E) FLORIDA PRODUCT APPROVAL NUMBERS LISTED ON THE |
| | CONNECTOR SCHEDULE NEED TO BE UPDATED USING 2007 CODE |
| | VERSION. VISIT DCA WEBSITE AND UPDATE ALL NUMBERS AS |
| | REQUIRED. |
| | |
| | F) REVISE DESIGN PARAMETERS NOTE #6. THIS BUILDING IS |
| | LOCATED ON EXPOSURE "C" NOT "B". AND, THERE IS NOT |
| | TABLE 1606.2D ON THE 2007 FBC. |
| | |
| | 6- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) 18' WIDE GARAGE DOOR THAT MEETS THE DESIGN PRESSURES |
| | CALCULATED BY THE ENGINEER ON SHEET A-2. NOA 09-0128.06 |
| | SUBMITTED DOESN'T MEET THE CALCULATED DESIGN PRESSURES. |
| | |
| | B) PRECAST LINTELS AS SPECIFIED ON PLANS. |
| | |
| | C) FLORIDA PRODUCT APPROVAL FL4760-R1 SUBMITTED IS FOR |
| | 6'-8" DOORS. CLARIFY WHERE ARE THE 6'-8" DOORS GOING TO |
| | BE INSTALLED. PLANS CALL FOR 8'-0" DOORS. |
| | |
| | 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. |
| | |
| | 8- REVISE THE ENERGY CALCULATIONS SUBMITTED: |
| | A) PLANS AND PRODUCT APPROVALS SUBMITTED ARE FOR |
| | CONCRETE TILE. ENERGY CALCULATIONS SPECIFY COMPOSITION |
| | SHINGLES. REVISE AS REQUIRED. |
| | B) THERE ARE NOT INSULATED DOORS. SEE PLANS AND PRODUCT |
| | APPROVALS SUBMITTED AND REVISE AS REQUIRED. |
| | C) THERE ARE NOT EXTERIOR WOOD DOORS. SEE PLANS AND |
| | PRODUCT APPROVALS SUBMITTED AND REVISE AS REQUIRED. |
| | D) COMPLETE ALL THE INFORMATION ON TOP OF FORM. |
| | INCLUDING THE NAME OF BUILDER. |
| | |
| | 8- ENGINEER OF RECORD NEED TO UPDATE THE CERTIFICATE OF |
| | AUTHORIZATION FOR "THE ERNING CORPORATION". SEC. |
| | 61G15-23.002 FLORIDA ADMINISTRATIVE CODE AND CHAPTER |
| | 471 FLORIDA STATUTE . CONTACT DBPR AND UPDATE AS |
| | REQUIRED. |
| | |
| | 9- SHEET A-1: FLOOR PLAN IS MISSING THE WALL BETWEEN |
| | THE DINING ROOM AND GARAGE. REVISE AS REQUIRED. SEC. |
| | 106.1.1 CITY AMENDMENTS TO FBC. |
| | |
| | 10 - SHEET S-3: REVISE THE ROOF SHEATHING NOTES ON THE |
| | TYPICAL WALL SECTIONS. RING SHANK NAILS AT 4"O.C. ARE |
| | REQUIRED ON ROOF ZONE #3 ALSO. NOT ONLY ON GABLE ENDS. |
| | SEE SEC. R803.2.3.1 AND REVISE AS REQUIRED. |
| | |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |