| Plan Review Notes For Permit 11090275 |
| Permit Number |
11090275 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-09-14 07:57:03 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE STRUCTURE IS LOCATED IN EXPOSURE CATEGORY C, | | | BECAUSE IT IS WITHIN 1500 FEET OF EXPOSURE C TERRAIN. | | | SEE FBC R301.2.1.4.3. | | | | | | 2) SUBMIT TWO SETS OF RAS 117 CALCULATIONS | | | PREPARED,SIGNED AND SEALED BY A FLORIDA REGISTERED | | | ENGINEER, ARCHITECT OR REGISTERED ROOF CONSULTANT FOR | | | THE ENHANCED FASTENING OF THE BASE SHEET FOR THE | | | CERTAINTEED MODIFIED ROOFING SYSTEM (NOA NO. | | | 08-0410.09) AS REQUIRED BY GENERAL LIMITATION #7 OF THE | | | PRODUCT APPROVAL. DCA RULE 9N-3 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|