2011-09-22 08:59:0611090245
 1554 PALM BEACH LAKES
 SIGN REPLACEMENT
  
 A SIGNED AND SEALED ENGINEERING DETAIL IS REQUIRED FOR
 WIND LOADING. INCLUDE SPECIFIC FASTENER DETAIL FOR EACH
 LETTER. DESIGN DOCUMENT MUST REFERENCE AS A MINIMUM
 ASCE 7-05, EXPOSURE "C", 2007 FLORIDA BUILDING CODE.
 INDICATE THE WIND LOAD CAPABILITIES OF 140 MPH OR
 GREATER SPECIFIC TO THE DESIGN. FBC 1609
  
 ELECTRIC SIGNS MUST BE LISTED BY A NATIONALLY
 REGISTERED TESTING AGENCY. INDICATE ON THE PERMIT
 SUBMITTAL WHO HAS LISTED THE SIGN. NEC 110.3
  
  