| Date |
Text |
| 2011-10-14 16:11:00 | BUILDING PLAN REVIEW |
| | PERMIT: 11080665 |
| | ADD: 1450 CENTREPARK BLVD 150 |
| | CONT: ANDERSON-MOORE CONSTRUCTION CORP. |
| | TEL: (561)662-1819 |
| | |
| | 2007 FLORIDA BUILDING CODE-BUILDING W/ 2009 FBC |
| | SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS CHAPTER 1 |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1450 CENTREPARK #165 11080820- NO FEE PERMIT FOR DEMO |
| | OF TENANT SEPERATION WALL AND NEW TENANT SEPERATION |
| | WALL, (DRYWALL SCREW INSPECTION) ONLY. |
| | COMMENTS FOR BOTH PERMITS 11080665 SUITE # 150 AND |
| | 11080820 SUITE # 165 WILL APPEAR UNDER THIS REVIEW. |
| | |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | OCT. 14/2011 |
| | |
| | 1) THE LIFE SAFETY SHEET A8 INDICATES FOR BOTH SUITES |
| | THE COMMON PATH OF TRAVEL IS EXCEEDED. 2007 FBC-B |
| | 1014.3 EXCEPTION# 1 DOES ALLOW FOR A 100 FOOT COMMON |
| | PATH OF TRAVEL FOR SPRINKLERED BUILDINGS. FOR BOTH |
| | SUITES THIS COMMON PATH OF TRAVEL IS EXCEEDED.THE CODE |
| | COMMENTARY INDICATES THE DIMENSION TO START COMMON PATH |
| | OF TRAVEL IS ONE FOOT FROM THE FURTHEST POINT IN THE |
| | TENANT SPACE. THE SECOND ISSUE # 165 THE PLANS INDICATE |
| | A DIAGONAL ACROSS THE TENANT SPACE. COMMON PATH OF |
| | TRAVEL IS TAKEN AT APPROXIMATELY 1'-0" OFF OF THE WALL |
| | LINE, JUSTT AS IF THE ROOM WAS FILED WITH SMOKE YOU |
| | WOULD CRAWL NEXT TO TTHE WALL LINE IN THE DIRECTION OF |
| | THE EXIT DOOR. |
| | |
| | 2) SHEET A8 THE LIFE SAFETY PLAN INDICATES WITHIN SUITE |
| | # 150 SINCE THE COMMON PATH OF TRAVEL IS EXCEEDED, IT |
| | WOULD APPEAR THAT A SECOND EXIT DOOR WOULD NEED TO BE |
| | INCORPORATED INTO THE PLAN LAYOUT MEETING THE |
| | REQUIREMENT OF 1015.2.1 EXCEPTION #3. THE SECONDARY |
| | EXIT DOOR CURRENTLY DOE NOT MEET THIS REQUIREMENT. |
| | |
| | 3-7) COMPLIED. |
| | |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |