| Plan Review Notes For Permit 11080309 |
| Permit Number |
11080309 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-08-15 16:44:06 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PROVIDE INFORMATION REGARDING THE EXISTING STRUCTURE | | | PRIOR TO THE AUTO DAMAGE. A FILLED CELL IS USUALLY ON | | | EITHER SIDE OF ALL OPENINGS. WHAT TAKES THE PLACE OF | | | THE MISSING FILLED CELL ON ONE SIDE OF THE DOOR WHICH | | | WILL PROVIDE CONTINUOUS LOAD PATH? | | | | | | 2. THE PLAN VIEW AND THE FRONT ELEVATION DO NOT MATCH. | | | ONE SHOWS THE DOOR AGAINST A FILLED CELL, THE OTHER | | | SHOWS IT IN THE MIDDLE OF A FRAME WALL. | | | | | | 3. BOND BREAK REQUIRED, FBC R 703.6.3. REVISE WALL | | | SECTION. | | | | | | 4. SCOPE IN PERMIT DESCRIPTION INCLUDES REPLACEMENT OF | | | A LIGHT, BUTNO ELECTRICAL SHOWN ON THE PLAN. | | | |
|