| Plan Review Notes For Permit 11070634 |
| Permit Number |
11070634 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2011-08-12 15:07:57 | PROVISO | | | EITHER: REVISION REQUIRED (SUBMIT INSTALLATION | | | SCHEDULE) OR SUBMIT SEPARATE PERMIT FOR SHUTTERS WITH | | | ALL REQUIRED INFORMATION (PRODUCT APPROVAL, PLAN, | | | INSTALLATION SCHEDULE) | | | | | | | | | SUBMIT AN INSTALLATION SCHEDULE CORRECTED AS FOLLOWS: | | | | | | 1. SEE OPENINGS 1 AND 2, SEE SHEET 4 OF PRODUCT | | | APPROVAL FOR SHUTTER TO GLASS SEPARATION REQUIRED. | | | | | | 2. SEE SHEET 5 OF PRODUCT APPROVAL, 3 1/2" EDGE | | | DISTANCE REQUIRED FOR BLOCK SUBSTRATE. | | | | | | 3. SHUTTER CONNECTION MOUNTING TYPE SHOULD CORRELATE | | | WITH THE ANCHOR CHARTS ON SHEET 5 (FOR INSTANCE, 1 TOP, | | | 2 BOTTOM, ETC.). CODE COMPLIANCE CANNOT BE DETERMINED | | | BASED ON THE INFORMATION PROVIDED. | | | | | | |
|