Plan Review Notes
Plan Review Notes For Permit 11070629
Permit Number 11070629
Review Stop P
Sequence Number 1
Notes
Date Text
2011-08-02 10:40:27FBC PLUMBING 2007 REVIEW #1
 DENIED:
  
 1. THIS BUILDING DOES NOT INDICATE TYPE OF OCCUPANCY
 AND NUMBER OF OCCUPANTS.
 403.1 MINIMUM NUMBER OF FIXTURES. PLUMBING FIXTURES
 SHALL BE PROVIDED FOR THE TYPE OF OCCUPANCY AND IN THE
 MINIMUM NUMBER SHOWN IN TABLE 403.1. TYPES OF
 OCCUPANCIES NOT SHOWN IN TABLE 403.1 SHALL BE
 CONSIDERED INDIVIDUALLY BY THE CODE OFFICIAL. THE
 NUMBER OF OCCUPANTS SHALL BE DETERMINED BY THE FLORIDA
 BUILDING CODE, BUILDING. OCCUPANCY CLASSIFICATION SHALL
 BE DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING
 CODE, BUILDING.
  
 2. THE KITCHEN CAN WASH SHOULD BE INSTALLED ON THE
 GREASE LINE.
 1003.3.1 GREASE INTERCEPTORS AND AUTOMATIC GREASE
 REMOVAL DEVICES REQUIRED. A GREASE INTERCEPTOR OR
 AUTOMATIC GREASE REMOVAL DEVICE SHALL BE REQUIRED TO
 RECEIVE THE DRAINAGE FROM FIXTURES AND EQUIPMENT WITH
 GREASE-LADEN WASTE LOCATED IN FOOD PREPARATION AREAS
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676