| 2011-10-05 11:20:59 | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 11070617 |
| | ADD: 2301 OKEECHOBEE BLVD, BLDG# 1 |
| | CONT: NORTH AMERICAN AUTOMOTIVE SERVICES |
| | TEL: (630)352-8126 |
| | |
| | 1A) PARTS MEZZANINE IS TO BE A PRE-ENGINEERED SYSTEM |
| | VENDOR INSTALLED, UNDER A SEPARATE PERMIT, REVIEW AND |
| | ASSOCIATED FEES. |
| | |
| | 1B) 110.4.2 STORAGE & FACTORY- INDUSTRIAL OCCUPANCIES. |
| | IT SHALL BE THE RESPONSIBILITY OF THE OWNER, AGENT, |
| | PROPRIETOR OR OCCUPANT OF GROUP S AND GROUP F |
| | OCCUPANCIES, OR ANY OCCUPANCY WHERE EXCESSIVE FLOOR |
| | LOADING IS LIKELY TO OCCUR, TO EMPLOY A COMPETENT |
| | ARCHITECT OR ENGINEER IN COMPUTING THE SAFE FLOOR LOAD |
| | CAPACITY. ALL SUCH COMPUTATIONS SHALL BE ACCOMPANIED BY |
| | AN AFFIDAVIT FROM THE ARCHITECT OR ENGINEER STATING THE |
| | SAFE ALLOWABLE FLOOR LOADS ON EACH FLOOR IN POUNDS PER |
| | SQ FT. THE |
| | COMPUTATIONS & AFFIDAVIT SHALL BE FILED AS A PERMANENT |
| | RECORD OF THE BLDG DEPT. |
| | |
| | |
| | 1C) 110.4.3.SIGNS REQUIRED. IN EVERY BUILDING OR PART |
| | OF A BUILDING USED FOR STORAGE, INDUSTRIAL OR HAZARDOUS |
| | PURPOSES, THE SAFE FLOOR LOADS, AS REVIEWED BY THE |
| | BUILDING OFFICIAL ON THE PLAN, SHALL BE MARKED ON |
| | PLATES OF APPROVED DE SIGN WHICH SHALL BE SUPPLIED & |
| | SECURELY AFFIXED BY THE OWNER OF THE BUILDING IN A |
| | CONSPICUOUS PLACE IN EACH STORY TO WHICH THEY RELATE. |
| | SUCH PLATES SHALL NOT BE REMOVED OR DEFACED, & IF LOST, |
| | REMOVED THE OWNER OF THE BUILDING SHALL REPLACE THEM. |
| | |
| | 2) ROOFING APPROVALS: |
| | |
| | NOA: 07-1018.10 |
| | DURO-LAST SINGLE PLY PVC ROOFING SYSTEM OVER CONCRETE |
| | DECK, |
| | PAGE 5, DECK TYPE 31 CONCRETE DECK INSULATED -217.5 |
| | LIMITATION # 9 |
| | |
| | NOA 09-0219.09 |
| | JOHN MANVILLE ROOF INSULATION BOARD |
| | ROOF ASSEMBLIES ARE APPROVED UNDER SPECIFIC ROOF |
| | COVER?S PRODUCT NOA. |
| | |
| | NOA 07-1018.14 |
| | DURO-LAST SINGLE PLY PVC ROOFING SYSTEM OVER WOOD DECK |
| | THE INDIVIDUAL SUB-SYSTEMS ARE NOT IDENTIFIED, ROOFING |
| | CONTRACTOR WILL NEED TO |
| | IDENTIFY SUB-SYSTEM AND IF LIMITATION # 7 APPLIES THEN |
| | ENHANCED FASTENING IN ZONES |
| | 2 & 3 WILL NEED TO BE CALCULATED AND PREPARED BY EITHER |
| | A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR |
| | REGISTERED ARCHITECT. |
| | |
| | |
| | |