| 2011-07-20 17:05:01 | RESIDENTIAL (R2) WINDOW/DOOR REPLACEMENT BUILDING |
| | REVIEW CHECKLIST. |
| | 2007 FBC WITH 2009 REVISIONS. |
| | |
| | 1- MISSING PLANS SPECIFIED ON THE PERMIT APPLICATION. |
| | PROVIDE PLANS SHOWING THE WINDOWS AND DOORS TO BE |
| | REPLACED AND THE DETAILS/SPECIFICATIONS FOR FRAME |
| | SUPPORT STRUCTURAL REPAIRS. SEC. 106.1.2 CITY |
| | AMENDMENTS TO FBC. |
| | |
| | 2- SPECIFY TYPE AND SIZE OF EXISTING BEDROOM WINDOWS |
| | AND TYPE AND SIZE OF NEW WINDOWS TO VERIFY COMPLIANCE |
| | WITH THE EMERGENCY EGRESS REQUIREMENTS. |
| | |
| | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | |
| | A) HORIZONTAL ROLLING WINDOW. NOA 09-0105.02 SUBMITTED |
| | WAS SUPERSEDED BY MIAMI-DADE. VISIT THE MIAMI-DADE |
| | WEBSITE AND DOWNLOAD CURRENT NOA. |
| | |
| | B) SLIDING GLASS DOOR. NOA 09-0324.16 SUBMITTED WAS |
| | SUPERSEDED ALSO BY MIAMI-DADE. NEED CURRENT NOA. |
| | |
| | C) FIXED WINDOW. NOA 10-0930.04 SUBMITTED IS FOR |
| | NON-IMPACT GLASS. NEED TO PROVIDE GLASS PROTECTION AS |
| | REQUIRED BY SEC. 1609.1.2 FBC. PROVIDE NOA WITH IMPACT |
| | GLASS OR PROVIDE INFORMATION FOR SHUTTERS. |
| | |
| | D) HURRICANE SHUTTERS IF FIXED WINDOW HAS NO IMPACT |
| | GLASS. IN ADDITION PROVIDE COMPLETE SHUTTERS |
| | INSTALLATION SCHEDULE AND MARK ON SHUTTERS DRAWINGS |
| | SPECIFIC MOUNTING CONDITION (EX: WALL MOUNTED) AND |
| | ANCHOR TYPE AND SPACING TO BE USED. SEE CITY POLICY FOR |
| | SHUTTERS INSTALLATION. |
| | |
| | 4- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 |
| | FLORIDA STATUTE. |
| | |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |