| Date |
Text |
| 2011-08-10 14:56:48 | BUILDING PLAN REVIEW |
| | PERMIT: 11070279 |
| | ADD: 1009 N DIXIE HWY. |
| | CONT: PAUL BENNETT BUILDING |
| | CONTRACTOR # 685-5050 |
| | CONTACT: BOB CARTER |
| | TEL: (561) 301-2588 CELL |
| | 833-7529 BUS. |
| | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW REVIEW |
| | ACTION: DENIED |
| | |
| | ONLY CHANGE IN PLANS IS THE ADDRESS, OTHER COMMENTS NOT |
| | ADDRESSED. |
| | |
| | 1) COMPLIED. |
| | |
| | 2) COMPLIED. |
| | |
| | 3) THE DESIGNER OF RECORD WILL NEED TO DECIDE IF THIS |
| | PROJECT IS TO BE DESIGNED AS A MIXED USE BUILDING USING |
| | THE NON-SEPERATION METHOD OR SEPERATION METHOD: |
| | |
| | NONSEPARATED OCCUPANCIES: |
| | 508.3.2 NONSEPARATED OCCUPANCIES. BUILDINGS OR PORTIONS |
| | OF BUILDINGS THAT COMPLY WITH THE PROVISIONS OF THIS |
| | SECTION SHALL QUALIFY AS NONSEPARATED OCCUPANCIES. |
| | |
| | 508.3.2.1 OCCUPANCY CLASSIFICATION. NONSEPARATED |
| | OCCUPANCIES SHALL BE INDIVIDUALLY CLASSIFIED IN |
| | ACCORDANCE WITH SECTION 302.1. CODE REQUIREMENTS SHALL |
| | APPLY TO EACH PORTION OF THE BUILDING BASED ON THE |
| | OCCUPANCY CLASSIFICATION OF THAT SPACE EXCEPT THAT THE |
| | MOST RESTRICTIVE APPLICABLE PROVISIONS OF SECTION 403 |
| | AND CHAPTER 9 SHALL APPLY TO THE ENTIRE BUILDING OR |
| | PORTION THEREOF. |
| | |
| | 508.3.2.2 ALLOWABLE AREA AND HEIGHT. THE ALLOWABLE AREA |
| | AND HEIGHT OF THE BUILDING OR PORTION THEREOF SHALL BE |
| | BASED ON THE MOST RESTRICTIVE ALLOWANCES FOR THE |
| | OCCUPANCY GROUPS UNDER CONSIDERATION FOR THE TYPE OF |
| | CONSTRUCTION OF THE BUILDING IN ACCORDANCE WITH SECTION |
| | 503.1. |
| | |
| | 508.3.2.3 SEPARATION. NO SEPARATION IS REQUIRED BETWEEN |
| | OCCUPANCIES. |
| | |
| | EXCEPTION: GROUP H-2, H-3, H-4 OR H-5 OCCUPANCIES SHALL |
| | BE SEPARATED FROM ALL OTHER OCCUPANCIES IN ACCORDANCE |
| | WITH SECTION 508.3.3. |
| | |
| | |
| | OR |
| | |
| | 2007/09 FBC-B 508.3.3 SEPERATION |
| | 508.3.3 SEPARATED OCCUPANCIES. BUILDINGS OR PORTIONS OF |
| | BUILDINGS THAT COMPLY WITH THE PROVISIONS OF THIS |
| | SECTION SHALL QUALIFY AS SEPARATED OCCUPANCIES. |
| | |
| | 508.3.3.1 OCCUPANCY CLASSIFICATION. SEPARATED |
| | OCCUPANCIES SHALL BE INDIVIDUALLY CLASSIFIED IN |
| | ACCORDANCE WITH SECTION 302.1. EACH FIRE AREA SHALL |
| | COMPLY WITH THIS CODE BASED ON THE OCCUPANCY |
| | CLASSIFICATION OF THAT PORTION OF THE BUILDING. |
| | |
| | 508.3.3.2 ALLOWABLE AREA. IN EACH STORY, THE BUILDING |
| | AREA SHALL BE SUCH THAT THE SUM OF THE RATIOS OF THE |
| | ACTUAL FLOOR AREA OF EACH OCCUPANCY DIVIDED BY THE |
| | ALLOWABLE AREA OF EACH OCCUPANCY SHALL NOT EXCEED ONE. |
| | |
| | 508.3.3.3 ALLOWABLE HEIGHT. EACH OCCUPANCY SHALL COMPLY |
| | WITH THE HEIGHT LIMITATIONS BASED ON THE TYPE OF |
| | CONSTRUCTION OF THE BUILDING IN ACCORDANCE WITH SECTION |
| | 503.1. THE HEIGHT, IN BOTH FEET AND STORIES, OF EACH |
| | FIRE AREA SHALL BE MEASURED FROM GRADE PLANE. THIS |
| | MEASUREMENT SHALL INCLUDE THE HEIGHT, IN BOTH FEET AND |
| | STORIES, OF INTERVENING FIRE AREAS. |
| | |
| | EXCEPTION: SPECIAL PROVISIONS PERMITTED BY SECTION 509. |
| | |
| | 508.3.3.4 SEPARATION. INDIVIDUAL OCCUPANCIES SHALL BE |
| | SEPARATED FROM ADJACENT OCCUPANCIES IN ACCORDANCE WITH |
| | TABLE 508.3.3. |
| | |
| | |
| | IF THTE DESIGNER OF RECORD DECIDES TO USE THE |
| | NON-SEPERATED METHOD THE FOLLOWING WILL NEED TO BE |
| | DEMONSTRATED. |
| | STEP 1. DETERMINE WHICH OCCUPANCY GROUPS |
| | CLASSIFICATIONS ARE IN THE BUILDING. |
| | |
| | STEP 2. DETERMINE THE MINIMUM BUILDING TYPE OF |
| | CONSTRUCTION BASED ON THE HEIGHT & AREA OF THE BUILDING |
| | FOR EACH OCCUPANCY GROUP IN ACCORDANCE WITH THIS |
| | CHAPTER AND TABLE 503. APPLY THE REQUIREMENTS FOR THE |
| | MOST STRINGENT TO THE ENTIRE BUILDING. |
| | |
| | STEP 3. APPLY THE MOST RESTRICTIVE PROVISIONS CONTAINED |
| | IN SECTION 403 ( NOT APPLICABLE) AND CHAPTER 9 |
| | THROUGHOUT ALL NONSEPARATED USES (SECTION 508.3.2.1). |
| | |
| | STEP 4. APPLY ALL OTHER REQUIREMENTS OF THE CODE TO |
| | EACH OCCUPANCY INDIVIDUALLY BASED ON THE SPECIFIC |
| | OCCUPANCY OF EACH SPACE( E.G. MEANS OF EGRESS) (SECTION |
| | 508.3.2.1). |
| | |
| | 4) ELEVATED PLATFORMS SHALL COMPLY WITH: |
| | 4A) 1003.5 ELEVATION CHANGE. CHANGE IN LEVEL IN THE |
| | MEANS OF EGRESS SHALL BE EITHER BY A RAMP OR A STAIR. |
| | THE PRESENCE AND LOCATION OF RAMPED WALKWAYS SHALL BE |
| | READILY APPARENT. |
| | |
| | 4B) 1003.5.1 WHERE A CHANGE IN LEVEL MEANS OF EGRESS |
| | NOT EXCEEDING 21 INCHES (533 MM) IS ACHIEVED BY A |
| | STAIR, THE MINIMUM TREAD DEPTH OF SUCH STAIR SHALL BE |
| | 13 INCHES (330 MM) AND THE PRESENCE AND LOCATION OF |
| | EACH STEP SHALL BE READILY APPARENT. NOT SHOWN ON |
| | PLANS. |
| | |
| | 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |