| Notes |
| Date |
Text |
| 2011-07-18 17:07:06 | RESIDENTIAL (R2) WINDOWS REPLACEMENT BUILDING REVIEW | | | CHECKLIST. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- COMPONENT AND CLADDING DESIGN PRESSURES CALCULATIONS | | | DONE BY SPECIALTY ENGINEERING NEED TO BE REVISED. | | | ACCORDING TO 2009 REVISIONS SEC. 1609.4.3 FBC THIS | | | BUILDING IS LOCATED ON EXPOSURE "C" NOT "B". REVISE | | | CALCULATIONS AS REQUIRED. | | | | | | 2- ENGINEER TO REVISE CALCULATIONS/LETTER FOR THE | | | INSTALLATION OF 3"X3"X1/4" ALUMINUM MULLION. NEED TO | | | USE EXPOSURE "C" FOR CALCULATIONS. SEC. 1609.4.3 FBC. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|