| Date |
Text |
| 2011-07-07 11:06:30 | BUILDING PLAN REVIEW |
| | PERMIT: 11060763 |
| | ADD: 417 BUNKER RD |
| | CONT: WATSON GENERAL CONTRACTING |
| | TEL: (561)762-8471 |
| | |
| | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) PLANS DO NOT PROVIDE IF THIS IS A CHANGE OF |
| | OCCUPANCY, OR TO WHAT DESIGN CRITERIA THIS PLAN WAS |
| | DESIGNED TOO? 2007/09 EXISTING BLDG CODE 2007/09 |
| | EXISTING BLDG CODE 101.5.(101.5.1-101.5.3) OR CHAPTER 9 |
| | CHANGE OF OCCUPANCY. |
| | |
| | 2) THE PERMIT APPLICATION INDICATES UNDER DESCRIPTION |
| | OF WORK INTERIOR RENOVATIONS W/ AC & ELECTRIC. PLANS |
| | ARE NOT CLEAR OTHER THAN NEW ENTRY DOORS AND A NEW |
| | UNISEX RESTROOM WHAT OTHER WORK IS TO BE COMPLETED |
| | UNDER THIS PERMIT FOR BUILDING? PLEASE REVIEW 2004 |
| | 106.3.5 MINIMUM CRITERIA BUILDING PLAN REVIEW. MINIMUM |
| | BUILDING TYPE, FIRE SPRINKLERED, OCCUPANCY, OCCUPANCY |
| | LOADS, MIXED USE BLDG IS THE OCCUPANCIES SEPERATED OR |
| | NON-SEPERATED, PROVIDE A LIFE SAFETY PLAN WITH |
| | FURNISHINGS. PROVIDE A NARRATIVE AS TO WHAT WORK IS TO |
| | BE ACCOMPLISHED UNDER THIS PERMIT. |
| | |
| | 3) NEW UNISEX RESTROOM DETAIL PROVIDED ON SHEET 2 IS |
| | FOR NEW TOILET STALL CONSTRUCTION, NOT FOR A TOLIET |
| | ROOM, PLEASE REVIEW SECTION 11-4.16 WATER CLOSETS IN |
| | TOLIET ROOMS, NOT STALLS, 11-4.16.2 CLEAR FLOOR SPACE |
| | DIRECTS YOU TO FIGURE #28. THE DESIGNER OF RECORD WILL |
| | NEED TO INDICATE THE CLEAR FLOOR SPACE, IF A FORWARD |
| | APPROACH OR SIDE APPROACH, NOTE THE INSWING DOOR CAN |
| | NOT SWING INTO THE CLEAR FLOOR SPACE. |
| | |
| | 4) SHEET A1 INDICATES A NEW ENTRY DOOR BUT NO |
| | INFORMATION IS PROVIDED AS TO IS THE FRONT ENTRY |
| | ACCESSIBLE 11-4.14 ENTRANCES. |
| | |
| | 5) SHEET A1 & A2 INDICATES A PAIR OF NEW IMPACT RATED |
| | DOORS MISSING PRODUCT APPROVALS. FL BLD CODE 1609.6.2.2 |
| | COMPONENTS & CLADDING, PROVIDE 2 COPIES OF PRODUCT |
| | TESTING REPORTS, MISSING REPORTS ARE AS FOLLOWS: |
| | EXTERIOR GLAZED DOORS. |
| | |
| | 6) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE |
| | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. PLEASE ALSO NOTE |
| | TYPE OF HARDWARE TO BE INSTALLED ON DOUBLE INSWING |
| | DOORS. |
| | |
| | 7) DEPENDING ON THE OCCUPANT LOADS TO BE DETERMINED THE |
| | MAIN EXITING DOORS MAY NEED TO BE OUTSWING DOORS IF THE |
| | OCCUPANT LOADS ARE 50 OR MORE, PLEASE REVIEW 2007/09 |
| | FBC/B 108.1.2. |
| | |
| | 8) PLANS INDICATE A PAIR OF POCKET DOORS BETWEEN RETAIL |
| | ROOM # 2 &3, IT IS NOT CLEAR IF THIS IS EXISTING OR NEW |
| | WORK, NOR DO WE KNOW THE DESIGN CRITERIA METHOD UNDER |
| | THE 2007/09 EXISTING BUILDING CODE, BUT IF THIS |
| | CONDITION IS NEW WORK PLEASE REVIEW 1008.1.2 EGRESS |
| | DOORS SHALL BE SIDE SWINGING. |
| | |
| | 9) PLEASE PROVIDE ADDITIONAL INFORMATION ON THE |
| | GARDRAIL SYSTEM TO THE A/C MEZANINE LEVEL. THE |
| | MANUFACTURING PLANT THAT WAS THERE BEFORE DID HAVE A |
| | FACTORY OCCUPANCY CLASSIFICATION WHERE THE PUBLIC WAS |
| | NOT ALLOWED INTO THE PLANT. THIS DID ALLOW FOR THE 21 |
| | INCH CLEAR SPACE OR MIDRAIL AS DEPICTED ON SHEET A2. |
| | THE ISSUE AT HAND ARE SINCE THE PUBLIC WILL BE PASSING |
| | BY THESE STAIRS, HOW OR WHAT WILL BLOCK, LOCK OFF THE |
| | STAIRS TO THE GENERAL PUBLIC? |
| | 2007/09 1013.3 EXCEPTION #3. |
| | |
| | 10) THIS COMMENT IS A ACCESSIBILITY COMMEENT AS WELL AS |
| | A REQUIREMENT THAT WILL BE STATED FROM YOUR PLUMBING |
| | PLAN REVIEWER, PLANS ARE MISSING AN ACCESSIBLE DRINKING |
| | FOUNTAIN 11-4.15. |
| | |
| | 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER C.B.O. |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: (561)805-6715 |
| | FAX:(561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |