| Plan Review Notes For Permit 11060326 |
| Permit Number |
11060326 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-06-14 12:18:17 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- PROVIDE COMPLETE PRODUCT APPROVAL. PRODUCT APPROVAL | | | FL479-R3 SUBMITTED IS MISSING THE NOA 08-0410.09 THAT | | | WAS CIRCLED ON THE SUBMITTAL. | | | | | | 2- CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY AND BASE | | | SHEET FASTENING OPTION IS GOING TO BE INSTALLED TO | | | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | | R301. | | | | | | 3- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | 08-0410.09 MARKED ON FLORIDA PRODUCT APPROVAL FL479-R3 | | | SUBMITTED. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 | | | | | | |
|