| Notes |
| Date |
Text |
| 2011-07-08 13:55:23 | 525 SOUTH FLAGLER DRIVE - MEZZANINE | | | PERMIT #11050759 | | | ROUND 3 REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | FOR ASSEMBLY OCCUPANCIES, THE COMMON PATH OF TRAVEL TO | | | ONE MEANS OF EGRESS IS LIMITED TO 20 FEET WHEN THE | | | OCCUPANT LOAD EXCEEDS 50 PERSONS PER SECTION 13.2.5.1.2 | | | OF NFPA 101 FLORIDA EDITION. | | | | | | IF NEW GLASS ENTRY DOORS ARE EQUIPPED WITH A LOCK OR | | | LATCH, THESE DOORS ARE REQUIRED TO HAVE LISTED PANIC OR | | | FIRE EXIT HARDWARE TO RELEASE THE LOCK/LATCH. POSTING A | | | SIGN THAT THE DOORS ARE TO REMAIN UNLOCKED WHEN THE | | | SPACE IS OCCUPIED IS ONLY ALLOWED FOR EXTERIOR DOORS | | | PER SECTION 7.2.1.5.4 OF NFPA 101 FLORIDA EDITION. | | | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND FIRE ALARM SYSTEM. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|