Plan Review Notes
Plan Review Notes For Permit 11050433
Permit Number 11050433
Review Stop B
Sequence Number 2
Notes
Date Text
2011-06-27 10:46:14****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PRESSURES ARE TOO LOW. REVISE EXPOSURE TO CATEGORY C
 OR PROVIDE RATIONAL ANALYSIS FOR REDUCED PRESSURES.
 FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE CHANGED
 EFFECTIVE MARCH 1, 2009.
  
 2. SPANS ARE NOT CORRECT; WITH A WALL MOUNT, THIS
 SHOULD BE LARGER THAN THE OPENING DIMENSION. SPAN FOR
 ACCORDION SHUTTERS SHOULD EQUAL THE BLADE LENGTH.
  
 3. EITHER REVISE BOTTOM SUBSTRATE TO BLOCK OR PROVIDE
 INFORMATION AS TO HOW YOU HAVE DETERMINED THAT THE
 BOTTOM SUBSTRATE IS CONCRETE. CBS HOMES TYPICALLY HAVE
 CONCRETE TOP, BLOCK BOTTOM SUBSTRATE. A FILLED CELL
 REQUIRES USE OF BLOCK SUBSTRATE UNLESS THE PRODUCT
 APPROVAL INCLUDES FILLED CMU AS A SUBSTRATE.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU NEED ASSISTANCE.
  
  