| Plan Review Notes For Permit 11050309 |
| Permit Number |
11050309 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-06-03 12:11:11 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE OWNER BUILDER'S SIGNATURE ON THE APPLICATION AND | | | ON THE OWNER BUILDER DISCLOSURE FORM HAS TO BE | | | NOTARIZED. | | | | | | 2) SPECIFY THE WIND DESIGN DATA ON THE PLANS FBC | | | R301.1. THE WINDSPEED IS 140 MPH AND THE EXPOSURE | | | CATEGORY IS 'B' FOR THIS STRUCTURE. | | | | | | 3) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR THE | | | WINDOWS AND DOORS ON THE PLANS. FBC R301.2.1 | | | | | | 4) PROVIDE STRUCTURAL DETAILS FOR THE NEW OPENINGS IN | | | THE EXTERIOR WALL. FBC R601.2 | | | | | | 5) SPECIFY THE 2 X 4 WOOD RAFTER TO THE RIDGE BOARD AND | | | WOOD BEAM ATTACHMENTS AT THE COVERED PORCH AND WINDOW | | | AWNINGS ON THE PLANS. FBC R301.1 | | | | | | 6) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE CLAY | | | ROOF TILES. SPECIFY THE ATTACHMENT METHOD FROM THE | | | PRODUCT APPROVAL THAT WILL BE USED TO INSTALL THE TILE. | | | DCA RULE 9N-3. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|