2011-06-23 12:52:53****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE PROVIDE INFORMATION AS TO HOW YOU HAVE
 DETERMINED THAT THE BOTTOM SUBSTRATE IS CONCRETE. CBS
 HOMES ARE TYPICALLY CONCRETE TOP SUBSTRATE, BLOCK ON
 THE BOTTOM. PLEASE EITHER REVISE BOTTOM CONNECTION FOR
 BLOCK SUBSTRATE OR PROVIDE INFORMATION AS TO HOW A
 CONCRETE SUBSTRATE (FORMED AND POURED CONCRETE, NOT
 FILLED CELLS) HAS BEEN DETERMINED.
  
 2. THE SHUTTER CONNECTION MOUNTING TYPE IS TO CORRELATE
 WITH THE ANCHOR SCHEDULES (FOR INSTANCE, C1 - C5), SEE
 PP 9-10 OF THE NOA. PLEASE REVISE AS CONNECTION TYPES
 ARE NOT CLEAR. AN ATTEMPT WAS MADE TO PASS WITH
 REDLINES, BUT OPENING 3 STATES THAT THE SHUTTER
 CONNECTION MOUNTING TYPE IS "WALL/CEILING." WALL ON THE
 TOP, CEILING CONNECTION ON THE BOTTOM? AS PROPOSED
 INSTALLATION IS NOT CLEAR, IT WAS IMPOSSIBLE TO REDLINE
 THE ANCHOR SPACING.
  
  