| Plan Review Notes For Permit 11040450 |
| Permit Number |
11040450 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-04-21 11:06:05 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. REVISE EXPOSURE CATEGORY (TO EXPOSURE C) OR PROVIDE | | | ENGINEERING FOR EXPOSURE B PRESSURES. FBC1609, FBC | | | R301.2.1.4. NOTE THAT THE CODE CHANGED EFFECTIVE MARCH | | | 1, 2009. | | | | | | 2. THE ANCHOR CHARTS ON THE PRODUCT APPROVAL HAVE | | | SPACING CIRCLED ON THE CONCRETE SUBSTRATE CHART. PRIOR | | | TO RESUBMITTAL, PLEASE CONFIRM THAT ANCHOR SPACING | | | COMPLIES WITH REQUIREMENTS FOR CONCRETE BLOCK SUBSTRATE | | | AND INCREASED DESIGN PRESSURES. IT APPEARS THAT | | | INCORRECT ANCHOR SPACING HAS BEEN SPECIFIED ON THE | | | INSTALLATION SCHEDULE. | | | | | | | | | | | | |
|