| 2011-04-21 15:21:46 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. SEE SHEET 10 OF PRODUCT APPROVAL. THE ANCHOR SPACING | | | FOR CONCRETE SUBSTRATE HAS BEEN USED, BUT THE SUBSTRATE | | | SPECIFIED IN INSTALLATION SCHEDULE IS CONCRETE BLOCK. | | | NOTE THAT THE INSTALLATION MAY NOT BE PERMITTED FOR | | | THIS SUBSTRATE AND THE ANCHOR SELECTED, SEE "NA" ON THE | | | ANCHOR CHARTS. REVISE THE INSTALLATION SCHEDULE TO | | | COMPLY WITH REQUIRMENTS OF THE PRODUCT APPROVAL. | | | | | | 2. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | | | | | | | | |
|