| Plan Review Notes For Permit 11040291 |
| Permit Number |
11040291 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-04-21 14:09:18 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PROVIDE THE FLORIDA STATE PRODUCT APPROVAL COVER | | | SHEET, FLORIDA ADMINISTRATIVE CODE 9N-3, | | | WWW.FLORIDABUILDING.ORG. | | | | | | 2. PROVIDE A FLOOR PLAN WHICH SHOWS THE LOCATION OF THE | | | PROPOSED DOOR, SWING (INSWING OR OUTSWING) AND ALSO | | | PROVIDE ANY OTHER INFORMATION REQUIRED TO SHOW THAT | | | WATER INFILTRATION RESISTANCE IS NOT REQUIRED. SEE THE | | | PRODUCT APPROVAL, POSITIVE DESIGN PRESSURES FOR INSWING | | | DOORS THAT REQUIRE WATER INFILTRATION ARE LOWER THAN | | | REQUIRED BY FBC R 301. PROVIDE ENOUGH INFORMATION TO | | | SHOW COMPLIANCE, SUCH AS ANY CONDITIONS WHICH WOULD | | | MAKE WATER INFILTRATION UNNECESSARY (SUCH AS A COVERED | | | PORCH). IN OTHER WORDS, SHOW HOW WATER WILL BE | | | PREVENTED FROM ENTERING THE BUILDING THROUGH THE DOOR, | | | ESPECIALLY IF IT IS AN INSWING DOOR. | | | | | | 3. PROVIDE BUILDING HEIGHT, LOCATION IN THE BUILDING | | | (DISTANCE TO CORNER), AND DOOR SIZE SO DESIGN PRESSURES | | | CAN BE DETERMINED FBC R301. | | | | | | |
|