| Date |
Text |
| 2011-04-27 15:59:43 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW CHECKLIST. |
| | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| | |
| | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 |
| | FL. ST.. |
| | ***NOTE: THIS MAY BE RECORDED LATER AT TIME OF PERMIT |
| | PICK UP. |
| | |
| | 2- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH |
| | COUNTY (2300 N JOG RD) TO VERIFY IF IMPACT FEES ARE |
| | DUE. BRING BACK STAMPED PLANS AND COPY OF THE PAID |
| | RECEIPT IF FEES ARE DUE. |
| | |
| | 3- PERMIT VALUATION DECLARED IN THE PERMIT APPLICATION |
| | IS TOO LOW. SEC. 108.3 CITY AMENDMENTS TO FBC. |
| | VALUATION WAS UPDATED TO $121.325 USING THE ICC |
| | BUILDING VALUATION DATA. PERMIT VALUATION TO INCLUDE |
| | ALL PROFESSIONAL DESIGN FEES, LABOR AND MATERIALS AND |
| | CONTRACTOR'S OVERHEAD AND PROFIT. TOTAL PERMIT FEE |
| | VALUE IS $3584.70. |
| | |
| | 4- MINIMUM FLAT ROOF SLOPE IS 1/4" PER FT. SEC. |
| | R905.11.1 OF 2007 FLORIDA RESIDENTIAL CODE. SLOPE |
| | SPECIFIED ON RIGHT ELEVATION ON SHEET 1 OF 6 IS 1" PER |
| | 10'. REVISE AS REQUIRED AND SPECIFY SLOPE ON THE ROOF |
| | FRAMING PLAN ALSO. |
| | |
| | 5- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9B-72 FOR: |
| | A) FLAT ROOF. * NOA 08-0204.08 SUBMITTED IS FOR |
| | CEMENTITIOUS WOOD FIBER DECKS. NEED ONE FOR WOOD DECKS. |
| | ** CLEARLY INDICATE WHICH APPROVED ASSEMBLY IS GOING TO |
| | BE INSTALLED. INSULATED OR NON-INSULATED ASSEMBLY. *** |
| | IF USING INSULATED SYSTEM, THEN SPECIFY HOW ACHIEVING |
| | THE R-30 VALUE REQUIRED BY THE ENERGY CALCULATIONS. |
| | **** PROVIDE RAS 117 CALCULATIONS AS REQUIRED BY |
| | GENERAL LIMITATION #7. CHECK ON NOA IF CALCULATIONS |
| | NEED TO BE SIGNED AND SEALED. |
| | |
| | B) SLIDING GLASS DOORS. NOA 09-0324.16 SUBMITTED WAS |
| | SUPERSEDED BY MIAMI-DADE WEBSITE. PROVIDE CURRENT NOA. |
| | |
| | C) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS |
| | AND DETAILS. OR, SPECIFY FLORIDA PRODUCT APPROVAL OR |
| | NOA NUMBER ON PLANS. |
| | |
| | 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. |
| | |
| | 7- ENERGY CALCULATIONS SUBMITTED: |
| | A) ROOF MATERIAL SPECIFIED ON PAGE 2 DOESN'T MATCH ROOF |
| | MATERIAL SPECIFIED ON PLANS AND PRODUCT APPROVAL. |
| | |
| | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. |
| | |
| | 8- PROVIDE OPENING FRAMING DETAILS FOR NEW SKYLIGHT. |
| | SEC. 106.1.1 CITY AMENDMENTS TO FBC. |
| | |
| | 9- SPECIFY THE FOOTING SIZES FOR THE INTERIOR BEARING |
| | WALLS. SEC. 106.1.1 CITY AMENDMENTS. |
| | |
| | 10- ENERGY CALCULATIONS ARE TAKING THE CEILING FAN |
| | CREDIT. SPECIFY ON PLANS CEILING SIZE ON ALL ROOMS |
| | REQUIRED BY SEC. C4.2.1.1 AND TABLE C4.2.1.1. |
| | |
| | 11- PROVIDE DETAIL/SPECIFICATIONS SHOWING HOW PROVIDING |
| | THE R-30 INSULATION ON THE CEILING AREAS WHERE THE A/C |
| | DUCTWORK IS RUNNING. SEC. 106.1.1 CITY AMENDMENTS. |
| | |
| | 12- PROVIDE COMPLETE SECTIONS/DETAILS/SPECIFICATIONS |
| | SHOWING HOW THE WINDOWS ARE ATTACHED TO THE GLASS |
| | BLOCK. IN THE BEDROOM AREA. SEC. 106.1.1 CITY |
| | AMENDMENTS TO FBC. |
| | |
| | 13- SHEET 1 OF 6: A) REVISE BUILDING CODE SPECIFIED |
| | UNDER THE DESIGN PRESSURES TABLE. CURRENT CODE IS THE |
| | 2007 FLORIDA RESIDENTIAL CODE NOT 2001 FBC. |
| | |
| | B) UPDATE GENERAL NOTES #5(B), #7 AND #12. REFER TO THE |
| | 2007 FLORIDA RESIDENTIAL CODE FOR CORRECT CODE SECTION. |
| | |
| | C) UPDATE WIND INFORMATION: * REFER TO 2007 FLORIDA |
| | RESIDENTIAL CODE. REVISE ALL NOTES CITING CORRESPONDING |
| | SECTIONS OF THE 2007 FLORIDA RESIDENTIAL CODE. ** |
| | CLARIFY AND COORDINATE EXPOSURE CATEGORY. UPLIFT |
| | WORKSHEET SPECIFIES EXPOSURE "B" WHILE WIND INFORMATION |
| | SPECIFIES EXPOSURE "C". *** SHEARWALLS: PLANS TO |
| | IDENTIFY ALL SHEARWALLS THAT COMPLY WITH THE |
| | SPECIFICATIONS WRITTEN ON THIS ITEM. ****UPDATE LAST |
| | NOTE: THERE IS NOT 2004 FBC. |
| | |
| | 14- SHEET 2 OF 6: IDENTIFY ROOM ON EXISTING HOUSE WHOSE |
| | WINDOWS ARE BEING CLOSED. IF IT'S A BEDROOM, THEN I |
| | NEED TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS |
| | WHEN THE WINDOWS ARE CLOSED OFF. |
| | |
| | 15- SHEET 4 OF 6: A) REVISE FLORIDA PRODUCT APPROVALS |
| | NUMBERS SPECIFIED ON THE STRAPPING SCHEDULE. NUMBERS |
| | SHOWN ARE NOT CURRENT. |
| | |
| | B) REVISE NOTE #9. SEE SIMPSON CATALOG FOR CORRECT NAIL |
| | TYPE TO BE USED. OTHERWISE, PROVIDE ENGINEERING |
| | ANALYSIS TO SHOW COMPLIANCE WITH THE CALCULATED LOADS. |
| | |
| | C) SPECIFY CONNECTORS AT THE ENDS OF (2)2X12 HEADER BY |
| | THE FAMILY AREA. AND CONNECTORS AT THE BOTTOM OF (2)2X4 |
| | SUPPORTING THE HEADER TO VERIFY COMPLIANCE WITH THE |
| | UPLIFT LOADS. |
| | |
| | D) SPECIFY CONNECTORS FOR THE SHORT FRAMING MEMBERS AT |
| | THE NEW PATIO ROOF ( SEE WEST SIDE) AND AT THE MAIN |
| | ROOF (SEE EAST SIDE). |
| | |
| | 16- SHEET 5 OF 6: A) SHOWER SECTION TO SPECIFY |
| | REINFORCEMENT AT THE THICKENED EDGE. |
| | |
| | B) REVISE DOOR BUCK DETAIL. NEED TO SPECIFY BUCK SIZE |
| | THAT PROVIDE FULL SUPPORT TO THE DOOR FRAME. SEE |
| | PRODUCT APPROVAL FOR FRAME SIZE. SEC. R613.6. |
| | |
| | C) REVISE WINDOW BUCK DETAIL. BEVELED BUCKS ARE NOT |
| | ALLOWED. NEED TO PROVIDE FULL SUPPORT TO THE WINDOW |
| | FRAME. SEC. R613.6. |
| | |
| | D) TYPICAL WALL SECTION: * ROOF SHEATHING NAILS TO BE |
| | RING SHANK NAILS. SEC. R803.2.3.1. ** SPECIFY SIZE OF |
| | CONTINUOUS VENTILATION TO VERIFY COMPLIANCE WITH SEC. |
| | R806. |
| | *** CLARIFY FOOTING AND FINISH GRADE. DRAWING IS NOT |
| | CLEAR HOW GETTING THE 12" BELOW GRADE. CLARIFY SIZE OF |
| | FOOTING. BOTTOM OF SIDING MATERIAL TO BOTTOM OF FOOTING |
| | IS 16"?. WHAT'S THE SIDING MATERIAL?. SEE ELEVATIONS |
| | FOR EXTERIOR FINISH. |
| | |
| | 17- SURVEY NEEDS TO HAVE SURVEYOR'S ORIGINAL SEAL AND |
| | SIGNATURE AS REQUIRED BY CHAPTER 472 FLORIDA STATUTE. |
| | |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |