Plan Review Notes
Plan Review Notes For Permit 11040092
Permit Number 11040092
Review Stop B
Sequence Number 1
Notes
Date Text
2011-04-20 09:04:482007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE STRUCTURE IS LOCATED IN EXPOSURE CATEGORY C,
 HOWEVER, THE ENGINEER'S LETTER SPECIFIES EXPOSURE B.
 PLEASE CORRECT.
  
 2) REVISE THE COMPONENT AND CLADDING PRESSURES FOR 140
 MPH, 3 SECOND, EXPOSURE C WITH A MEAN ROOF HEIGHT OF
 22'-8".
  
 3) PLEASE CLARIFY THE SCOPE OF WORK. THE ENGINEER'S
 LETTER INDICATES THAT ONE WINDOW IS REPLACED AND ONE
 WINDOW IS BEING REPLACED WITH GLASS BLOCK. THE PRODUCT
 APPROVALS THAT WERE SUBMITTED ARE FOR GLASS BLOCK,
 SINGLE HUNG WINDOWS, HORIZONTAL SLIDING WINDOWS, FIXED
 WINDOWS, STRUCTURAL MULLIONS AND FRENCH DOORS. THE
 HOUSE PLANS DO NOT INDICATE A HORIZONTAL SLIDING
 WINDOW.
  
 4) PLEASE SPECIFY WHICH WINDOWS AND DOORS ARE BEING
 REPLACED AND PROVIDE THE COMPONENT AND CLADDING
 PRESSURES FOR THE OPENINGS.
  