| Notes |
| Date |
Text |
| 2011-04-20 09:04:48 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE STRUCTURE IS LOCATED IN EXPOSURE CATEGORY C, | | | HOWEVER, THE ENGINEER'S LETTER SPECIFIES EXPOSURE B. | | | PLEASE CORRECT. | | | | | | 2) REVISE THE COMPONENT AND CLADDING PRESSURES FOR 140 | | | MPH, 3 SECOND, EXPOSURE C WITH A MEAN ROOF HEIGHT OF | | | 22'-8". | | | | | | 3) PLEASE CLARIFY THE SCOPE OF WORK. THE ENGINEER'S | | | LETTER INDICATES THAT ONE WINDOW IS REPLACED AND ONE | | | WINDOW IS BEING REPLACED WITH GLASS BLOCK. THE PRODUCT | | | APPROVALS THAT WERE SUBMITTED ARE FOR GLASS BLOCK, | | | SINGLE HUNG WINDOWS, HORIZONTAL SLIDING WINDOWS, FIXED | | | WINDOWS, STRUCTURAL MULLIONS AND FRENCH DOORS. THE | | | HOUSE PLANS DO NOT INDICATE A HORIZONTAL SLIDING | | | WINDOW. | | | | | | 4) PLEASE SPECIFY WHICH WINDOWS AND DOORS ARE BEING | | | REPLACED AND PROVIDE THE COMPONENT AND CLADDING | | | PRESSURES FOR THE OPENINGS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|