| Date |
Text |
| 2011-04-18 10:12:34 | 2007 FBC W/2009 REVISIONS |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) SUBMIT TWO COPIES OF A SURVEY SHOWING THE DISTANCES |
| | FOR THE PROPOSED ADDITION TO THE PROPERTY LINES. FBC |
| | R302 |
| | |
| | 2) SUBMIT TWO COPIES OF A DRAINAGE PLAN SHOWING |
| | COMPLIANCE WITH R401.3. |
| | |
| | 3) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE |
| | ADDITION. FBC 13-101.2.2 |
| | |
| | 4) SPECIFY THE ATTACHMENT OF THE WALLS TO THE FLOOR |
| | SYSTEM TO THE SILL PLATE TO CREATE A CONTINUOUS LOAD |
| | PATH AS REQUIRED BY FBC R301.1. |
| | |
| | 5) SHOW COMPLIANCE WITH FBC R404.1.1.1, WHICH REQUIRES |
| | A REINFORCED BOND BEAM AT THE TOP OF THE FOUNDATION |
| | STEM WALL. |
| | |
| | 6) SHOW COMPLIANCE WITH FBC R 320 FOR TERMITE |
| | TREATMENT. |
| | |
| | 7) SHOW COMPLIANCE WITH FBC R 319.1 FOR WOOD JOISTS |
| | WITHIN 18" OF THE GROUND, WOOD SIDING,SHEATHING AND |
| | WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A |
| | CLEARANCE OF LESS THAN 6 INCHES FROM THE GROUND AND |
| | WOOD IN CONTACT WITH CONCRETE OR MASONRY. |
| | |
| | 8) SHOW COMPLIANCE WITH FBC R408.1 FOR CRAWL SPACE |
| | VENTILATION AND R408.4 FOR CRAWL SPACE ACCESS. |
| | |
| | 9) SHOW COMPLIANCE WITH FBC R806 FOR ROOF VENTILATION. |
| | |
| | 10) SHOW COMPLIANCE WITH FBC R301.2.1.2 FOR PROTECTION |
| | OF GLAZED OPENINGS. IF STORM PANELS ARE USED. SUBMIT |
| | TWO COPIES OF PRODUCT APPROVALS, KEY PLANS AND AN |
| | INSTALLATION SCHEDULE. |
| | |
| | 11) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE |
| | FIXED GLASS WINDOW, THE GLAZED OUTSWING FRENCH DOORS, |
| | THE METAL ROOFING, AND THE WOOD STRAPS AND CONNECTORS |
| | AS REQUIRED BY DCA RULE 9B-72. |
| | |
| | 12) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED |
| | AND APPROVED BY THE DESIGNER OF RECORD FOR THE PROJECT. |
| | FBC 106.3.3 CITY AMENDMENTS. |
| | |
| | 13) THE PLANS WILL BE REQUIRED TO BE REVIEWED BY PALM |
| | BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE DUE. |
| | |
| | 14) PLEASE RESPOND TO THE REVIEW COMMENTS IN WRITING |
| | INDICATING HOW THE ITEMS HAVE BEEN RESOLVED AND THE |
| | SHEETS THAT WERE REVISED. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | [email protected] |