Plan Review Notes
Plan Review Notes For Permit 11030743
Permit Number 11030743
Review Stop P
Sequence Number 1
Notes
Date Text
2011-04-04 13:39:08FBC 2007 PLUMBING REVIEW #1
 DENIED:
  
 1. THE WATER CLOSET IN MENS ROOM #107 WILL REQUIRE A
 VENT 901.2.1
  
 2. THE ISOMETRIC DRAWING SHOWS THE TRAPS FOR
 LAVITORIES, SINKS, URINAL, AND EWC APPEAR TO BE
 UNDERGROUND 1002.1
  
 3. THE WATER CLOSETS AND URINAL ARE CONNECTED TO THE
 HOT WATER SYSTEM ON THE ISO.
  
 4. THE 2 LAVITORIES IN WOMENS ROOM #106 HAVE THE HOT
 WATER ON THE RIGHT SIDE.
  
 5. THE WATER SUPPLY TO THE WATER COOLER IS NOT SHOWN.
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR