| Plan Review Notes For Permit 11030446 |
| Permit Number |
11030446 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-03-22 08:02:32 | BUILDING PROVISO: | | | 1406.2.2 ARCHITECTURAL TRIM. IN BUILDINGS | | | OF TYPE I, II, III AND IV CONSTRUCTION THAT | | | DO NOT EXCEED THREE STORIES OR 40 FEET | | | (12 192 MM) IN HEIGHT ABOVE GRADE PLANE, | | | EXTERIOR WALL COVERINGS SHALL BE PERMITTED | | | TO BE CONSTRUCTED OF WOOD WHERE PERMITTED | | | BY SECTION 1405.4 OR OTHER EQUIVALENT | | | COMBUSTIBLE MATERIAL. | | | | | | 1405.4 WOOD VENEERS. WOOD VENEERS ON | | | EXTERIOR WALLS OF BUILDINGS OF TYPE I, II, III | | | AND IV CONSTRUCTION SHALL BE NOT LESS THAN 1 INCH | | | (25 MM) NOMINAL THICKNESS, 0.438-INCH | | | (11.1 MM) EXTERIOR HARDBOARD SIDING OR | | | 0.375-INCH (9.5 MM) EXTERIOR-TYPE WOOD | | | STRUCTURAL PANELS OR PARTICLEBOARD AND SHALL | | | CONFORM TO THE FOLLOWING: | | | TABLE 1405.2 | | | MINIMUM THICKNESS OF WEATHER | | | COVERINGS | | | | | | | | | FAILED: PLANS APPEAR TO BE CODE COMPLIANT WITH PROVISO, | | | PLANS ARE STAMPED: | | | WILL ENTER A PASSED ONCE CONTRACTOR LICENSURE IS | | | VERIFIED. | | | | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] | | | |
|