| Notes |
| Date |
Text |
| 2011-03-11 15:25:10 | RESIDENTIAL (R3) ROOF REPAIRS, BUILDING REVIEW | | | CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS | | | | | | 1- PROPOSED REPAIRS ARE NOT ALLOWED BY SEC. 611.1.1 OF | | | 2007 FBC-EXISTING BUILDING. | | | | | | 2- FLAT ROOF NOA 08-0118.07 SUBMITTED EXPIRED ON | | | 03/08/11. NEED TO PROVIDE CURRENT NOA. | | | | | | 3- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | SUBMITTED. NEED TO MEET THE DESIGN PRESSURES REQUIRED | | | BY SEC. R301 OF 2007 FLORIDA RESIDENTIAL CODE. | | | | | | 4- NEED BUILDING PERMIT TO DO THE HURRICANE STRAPPING. | | | CONTRACTOR NEEDS TO HAVE PROPER LICENSE TO DO THE | | | STRUCTURAL WORK. ROOFING CONTRACTOR IS NOT ALLOWED TO | | | PERFORM THIS JOB. CONTACT PALM BEACH COUNTY LICENSING | | | BOARD REGARDING ROOFING CONTRACTOR SCOPE OF WORK. | | | | | | 5- PROVIDE ORIGINAL ENGINEERING LETTER (SIGNED AND | | | SEALED AS REQUIRED BY SEC. 472 FLORIDA STATUTES) | | | SPECIFYING STRAPS REQUIRED FOR THIS HOUSE. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|