Plan Review Notes
Plan Review Notes For Permit 11020269
Permit Number 11020269
Review Stop B
Sequence Number 1
Notes
Date Text
2011-02-15 09:58:53****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE EXPLAIN HOW YOU HAVE DETERMINED BUILDING
 HEIGHT AND, IF BUILDING IS 60FEET OR GREATER IN HEIGHT,
 PROVIDE ENGINEERING FOR DESIGN PRESSURES. NOTE THAT
 THIS PARCEL IS LOCATED IN EXPOSURE C. BUILDING APPEARS
 TO BE FOUR STORIES MINIMUM, WHICH WOULD REQUIRE 40'
 MINIMUM BUILDING HEIGHT. AT LEAST ONE OPENING APPEARS
 TO BE LOCATED IN ZONE 5 (BALCONY CORNER). SEE FBC1609.
 IT IS NOT CLEAR HOW +35/-47 FOR DESIGN PRESSURES HAS
 BEEN DETERMINED.
  
  
  