2011-01-27 13:59:18FBC PLUMBING REVIEW #1
 DENIED:
  
 1. PLUMBING 607.3.2 THERMAL EXPANSION CONTROL WILL BE
 REQUIRED.
  
 2. THE HOT WATER FOR THE RESTROOM AND WOK APPEARS TO BE
 SUPPLIED FROM 2 SEPERATE PLACES. IS THIS A HOT WATER
 CIRCULATING SYSTEM?
  
 3. THE DRAIN FOR THE SODA DISPENSER ON THE SANITARY
 RISER SHOULD BE A HUB DRAIN OR FLOOR SINK WITH TRAP.
  
 NOTES:
  
 2. PLEASE SPECIFY TOTAL SEATING. FBC PLUMBING 2007
 403.2(2) SEPERATE FACILITIES SHALL NOT BE REQUIRED FOR
 FOOD SERVICE ESTABLISHMENTS WHICH SEAT 10 PERSONS OR
 LESS.
  