| 2011-01-28 15:27:13 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | FBC FLORIDA BUILDING CODE 2007 |
| | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| | |
| | 1. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R |
| | 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS |
| | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE |
| | (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM |
| | /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF). |
| | |
| | 2. SHOW OPENINGS BETWEEN EXISTING HOUSE AND "SUNROOM" |
| | AND PROVIDE ROOM DESIGNATIONS FOR THE ROOMS OPEN TO THE |
| | SUNROOM. IF A BEDROOM OPENS INTO THE SUNROOM, SHOW |
| | ALTERNATIVE EMERGENCY EGRESS FBC R 310. |
| | |
| | 3. PROVIDE MORE INFORMATION REGARDING THE SUNROOM, IS |
| | THIS AREA UNDER AIR? REVISE PLAN TO PROVIDE |
| | INFORMATION. |
| | |
| | 4. PROVIDE A STRUCTURAL DETAIL FOR THE WALL FRAMING TO |
| | SHOW HOW THIS PROPOSED IMPROVEMENT WILL RESIST WIND |
| | LOADS, FBC R 301. STATE WIND DESIGN CRITERIA ON THE |
| | PLAN (140 MPH EXPOSURE C). DESIGN IS TO BE IN |
| | ACCORDANCE WITH THE METHODS LISTED IN FBC R 301.1 AND A |
| | DESIGNER LICENSED FOR THIS SCOPE OF WORK IS TO SIGN THE |
| | PLAN, FS 471, 481, 489. |
| | |
| | 5. REVISE APPLICATION TO REFLECT CORRECT VALUE (VALUE |
| | OF MATERIAL AND LABOR) AND CORRECT SCOPE OF WORK |
| | (ENCLOSE PORCH). |
| | |
| | 6. DUE TO INSUFFICIENT INFORMATION PROVIDED FOR REVIEW, |
| | PLEASE BE AWARE THAT IT IS POSSIBLE THAT THE REVISED |
| | PLAN MAY HAVE COMMENTS. |