| Plan Review Notes For Permit 11010075 |
| Permit Number |
11010075 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-01-11 10:20:33 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. MORE INFORMATION REQUIRED TO DETERMINE ZONE, | | | FBC1609. CONTRACTOR'S INFORMATION REGARDING LOCATION OF | | | OPENING IN ZONE 4 WAS HELPFUL; HOWEVER, BASED ON THE | | | FLOOR PLAN AND WRITTEN DESCRIPTION PROVIDED, IT APPEARS | | | THAT THE OPENING IS LOCATED IN CLOSE PROXIMITY TO A | | | BUILDING CORNER. IT APPEARS THAT THE CONTRACTOR IS | | | GIVING DISTANCE TO THE CORNER OF THE BALCONY RATHER | | | THAN THE ACTUAL BUILDING CORNER. EITHER REVISE THE PLAN | | | TO SHOW DISTANCE FROM THE INTERIOR BALCONY CORNER OR | | | HAVE THE ENGINEER DETERMINE ZONE. NOTE THAT SIMPLIFIED | | | METHOD OF ASCE7-05 IS RESTRICTED TO RECTANGULAR | | | BUILDINGS UNDER 60 FEET, WHICH DOES NOT APPLY IN THIS | | | CASE. | | | | | | |
|