2011-01-10 14:50:10BUILDING PLAN REVIEW
 PERMIT: 10120450
 ADD: 1800 CENTREPARK DRIVE EAST/ GROUND FLOOR
 CONT: TO BE DETERMINED
 TEL: (954)914-9848
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) COVER SHEET CS INDICATES THE MINIMUM BUILDING TYPE
 AS A TYPE V NO CHANGE, PLEASE REVIEW FBC-B TABLE 503,
 THE MINIMUM BUILDING TYPE CAN BE A TYPE IIA WITH A
 HEIGHT INCREASE OF ONE STORY IF INSTALLED IN ACCORDANCE
 WITH 903.3.1.1, NFPA 13, NOT A 13-R.
  
 2) NEITHER THE LIFE SAFETY PLAN NOR A-111 LOBBY FLOOR
 PLAN PROVIDE PLANS WITH RATED WALLS AND IDENTIFYING
 DOORS AND REQUIRED RATINGS
 THE BUILDING CODE THIS BUILDING WAS BUILT UNDER AS WELL
 AS TODAY'S CODE REQUIRES THE CORRIDORS TO BE ONE HOUR
 FIRE RATING THROUGH THE LOBBY TO THE EXIT DISCHARGE
 (FRONT DOORS). PLEASE SEE FBC-B TABLE 1017.1 REQUIRING
 A 1 HOUR CORRIDOR FOR A-2, A-3 AND R-1 OCCUPANCIES.
 SECTION 1014.2 DOES ALLOW FOR EGRESS THROUGH
 INTERVENING ROOMS PROVIDED SUCH ADJOINING ROOMS OR
 AREAS ARE NOT A HIGHER HAZARD OCCUPANCY AND PROVIDE A
 DISCERNIBLE PATH OF EGRESS TRAVEL TO AN EXIT. PLEASE
 PROVIDE WHERE THE FIRE RATED WALLS WILL BE LOCATED,
 FIRE DAMPERS FOR RATED WALLS AND OPENING PROTECTIVES
 (RATED DOORS). PLEASE REVIEW EXCEPTION FOR KITHEN
 AREAS.
  
 3) PLEASE PROVIDE ADDITIONAL WORDING FOR FIRE RATED
 WALLS, FBC-B 712.6 FIRE WALLS, FIRE BARRIERS, FIRE
 PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY
 OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE
 EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY
 HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE
 ANY DECORATIVE CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: "FIRE
 AND SMOKE BARRIER - PROTECT ALL OPENINGS."
  
 4) A-602 DOOR PLAN IDENTIFIES A FEW OF THE DOORS WITHIN
 THE FIRST FLOOR NOT ALL DOORS NOR DOES THE DOOR
 SCHEDULE INDICATE FIRE RATINGS.
 FBC-B TABLE 715.4 FOR REQUIRED OPENING PROTECTION
 RATINGS.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved