2011-01-05 08:51:48BUILDING PLAN REVIEW
 PERMIT: 10120447
 ADD: 10130 NORTHLAKE BLVD SUITE 100& 102
 CONT: S.W.KAPER
 TEL: (561)847-6648
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 BUILDING APPROVED WITH EXCEPTION!
 1008.1.9 PANIC AND FIRE EXIT HARDWARE. WHERE PANIC AND
 FIRE EXIT HARDWARE IS INSTALLED, IT SHALL COMPLY WITH
 THE FOLLOWING:
 1. THE ACTUATING PORTION OF THE RELEASING DEVICE SHALL
 EXTEND AT LEAST ONE-HALF OF THE DOOR LEAF WIDTH.
 2. THE MAXIMUM UNLATCHING FORCE SHALL NOT EXCEED 15
 POUNDS (67 N).
 EACH DOOR IN A MEANS OF EGRESS FROM A GROUP A OR E
 OCCUPANCY HAVING AN OCCUPANT LOAD OF 50 OR MORE AND ANY
 GROUP H OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR
 LOCK UNLESS IT IS PANIC HARDWARE OR FIRE EXIT HARDWARE.
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]