2011-01-06 09:04:01RESIDENTIAL (R3) BUILDING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTES.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. SEC. 108.3 CITY AMENDMENTS TO FBC. PROVIDE COPY OF
 SIGNED CONTRACT THAT INCLUDES ALL THE WORK TO BE
 PERFORMED..
  
 3- SPECIFY TYPE OF EXISTING WINDOWS TO BE REPLACED TO
 VERIFY COMPLIANCE WITH THE BEDROOM EGRESS REQUIREMENTS
 SEC. R310 2007 FLORIDA RESIDENTIAL CODE AND SEC. 601.2
 OF 2007 FBC-EXISTING.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) THE STEEL DOOR IN KITCHEN AREA.
  
 B) HURRICANE SHUTTERS AS REQUIRED BY SEC. R301.2.1.2.
 AND PROVIDE COMPLETE INSTALLATION SCHEDULE. CLEARLY
 MARK ON SHUTTERS DRAWINGS SPECIFIC MOUNTING CONDITIONS
 (EX; WALL MOUNTED) AND ANCHOR TYPE AND SPACING TO BE
 USED.
  
 5- SPECIFY ON PLANS SAFETY GLASS FOR WINDOWS #3, 5, 6
 AND 7 AS REQUIRED BY SEC. R308.4 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712