| Plan Review Notes For Permit 10120411 |
| Permit Number |
10120411 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-01-06 09:04:01 | RESIDENTIAL (R3) BUILDING REVIEW CHECKLIST. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTES. | | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | | UP. | | | | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. SEC. 108.3 CITY AMENDMENTS TO FBC. PROVIDE COPY OF | | | SIGNED CONTRACT THAT INCLUDES ALL THE WORK TO BE | | | PERFORMED.. | | | | | | 3- SPECIFY TYPE OF EXISTING WINDOWS TO BE REPLACED TO | | | VERIFY COMPLIANCE WITH THE BEDROOM EGRESS REQUIREMENTS | | | SEC. R310 2007 FLORIDA RESIDENTIAL CODE AND SEC. 601.2 | | | OF 2007 FBC-EXISTING. | | | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | A) THE STEEL DOOR IN KITCHEN AREA. | | | | | | B) HURRICANE SHUTTERS AS REQUIRED BY SEC. R301.2.1.2. | | | AND PROVIDE COMPLETE INSTALLATION SCHEDULE. CLEARLY | | | MARK ON SHUTTERS DRAWINGS SPECIFIC MOUNTING CONDITIONS | | | (EX; WALL MOUNTED) AND ANCHOR TYPE AND SPACING TO BE | | | USED. | | | | | | 5- SPECIFY ON PLANS SAFETY GLASS FOR WINDOWS #3, 5, 6 | | | AND 7 AS REQUIRED BY SEC. R308.4 OF 2007 FLORIDA | | | RESIDENTIAL CODE. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|