| Plan Review Notes For Permit 10120343 |
| Permit Number |
10120343 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-01-06 08:55:12 | BUILDING PLAN REVIEW | | | PERMIT: 10120343 | | | ADD: 600 S ROSEMARY AV #140 | | | CONT: TBD | | | TEL: (954)5839990 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS REQUIRE CITY PLACE STAMP BEFORE ISSUACNE. | | | | | | 2) BEFORE PERMIT ISSUANCE CONTRACTOR TO SIGN ON, VERIFY | | | LICENSURE BEFORE ISSUANCE. | | | | | | 3) BUILDING PROVISO: BEFORE FRAMING INSPECTION A | | | REVISION IS REQUIRED; | | | 3A)COVERSHEET G1.0, CORRECT MINIMUM BUILDING TYPE FROM | | | V-N TO BE III-A SPRINKLERED AS ORIGINAL PERMIT ISSUANCE | | | 99090717. | | | 3B) SHEET A3.3 SOFFIT DETAIL TO PROVIDE SPACING OF | | | FRAMING MEMBERS & TYPE OF STRUCTURE ABOVE, AND TYPE OF | | | ANCHOR & IF RATED CEILING, INDICATE FIRE RATING, FLOOR | | | CEILING ASSEMBLIES AS WELL AS OCCUPANCY SEPERATION | | | MERCANTILE AND A-2 ASSSEMBLY ABOVE. NOTE NEW HIGH HAT | | | FIXTURES ! | | | |
|