2011-03-31 12:25:04900 NORTH FLORIDA MANGO ROAD
 PERMIT #10120017
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 EXISTING BUSINESS OCCUPANCIES REQUIRE A MINIMUM OF TWO
 SEPARATE EXITS PER SECTION 39.2.4 NFPA 101 FLORIDA 2007
 EDITION.
  
 A FIRE ALARM SYSTEM SHALL BE PROVIDED IN EXISTING
 BUSINESS OCCUPANCIES TWO OR MORE STORIES IN HEIGHT
 ABOVE THE LEVEL OF EXIT DISCHARGE PER SECTION 39.3.4
 NFPA 101 FLORIDA 2007 EDITION.
  
 STAIRWAY STORAGE ACCESS DOORS ARE NOT PERMITTED TO OPEN
 INTO THE STAIR ENCLOSURE.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW