| Date |
Text |
| 2011-01-04 14:52:54 | PLEASE REVISION DRAWINGS FOR BUILDING PLAN EXAMINERS |
| | SIGNATURE JL |
| 2010-12-16 14:15:12 | BUILDING PLAN REVIEW |
| | PERMIT: 09070775/ REV. 10110668 |
| | ADD: 4295 45TH ST. |
| | CONT: STEPHEN GEHRING CONSTRUCTION |
| | TEL: (561)856-6655 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | BUILDING PROVISO: |
| | |
| | 1) SHEET A-2.1 DETAIL# 15 INDICATES THE USE OF 5/8 INCH |
| | EXTERIOR PLYWOOD SHEATHING, PLEASE REVIEW THE SET OF |
| | PLANS REVIEWED BY THTE BUILDING DEPARTMENT, SHEET A3.1 |
| | WITH THE USE OF 1/2 INCH GYPSUM SHEATHING, TYPE IIB |
| | BUILDING FBC603.1(1)(1.2) FIRE RETARDANT TRATED WOOD |
| | ALLOWED IN: (1.2) NON-BEARING EXTERIOR WALLS WHERE NO |
| | FIRE RATING IS REQUIRED. THE CURRENT REVISSIOON |
| | INDICATES THE USE OF PLYWOOD SHEATHING AND NO COMMENT |
| | ABOUT USE OF FIRE RETARDANT TREATED PLYWOOD. |
| | |
| | 2) PLEASE REVIEW SHEET SS1 DETAILS 5 & 7 IN REGARDS TO |
| | USE OF 5/8 INCH PLYWOOD IN EXTERIOR WALLS, PLEASE |
| | REVIEW CODE SECTION SITED ABOVE FOR USE OF |
| | NON-COMBUSTIBLE MATERIALS IN EXTERIOR WALLS. |
| | |
| | |
| | JIM WITMER C. B. O. |
| | COMMERCIAL COMBINATION PLAN REVIEW |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |