Plan Review Notes
Plan Review Notes For Permit 10110644
Permit Number 10110644
Review Stop B
Sequence Number 4
Notes
Date Text
2011-02-09 12:32:30****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 COMMENTS FROM PREVIOUS LISTS:
  
 1. PROVIDE PRODUCT APPROVALS REQUIRED FOR SLIDING GLASS
 DOOR, EXTERIOR DOORS, FAC9B72. (PROVISO ITEM)
  
 2. THIS IS A SUBSTANTIAL IMPROVEMENT, SEE FEMA NFIP
 DEFINITION, HTTP://WWW.FEMA.GOV/PLAN/PREVENT/FLOODPLAIN
 /NFIPKEYWORDS/SI.SHTM. COMPLIANCE WITH NFIP
 REQUIREMENTS IS REQUIRED. BASED ON THE ELEVATION
 CERTIFICATE PROVIDED, FLOOD OPENINGS, ITEM A8 ON
 ELEVATION CERTIFICATE, DO NOT COMPLY WITH NFIP
 REQUIREMENTS. SEE THE FEMA WEBSITE FOR MORE INFORMATION
 REGARDING REQUIREMENTS AND COMPLIANCE:
  
 HTTP://WWW.FEMA.GOV/PLAN/PREVENT/FLOODPLAIN/NFIPKEYWORD
 S/SI.SHTM
 HTTP://WWW.FEMA.GOV/LIBRARY/VIEWRECORD.DO?ID=1579
  
 ALSO SEE THE WALKWAY BETWEEN THE GARAGE AND MAIN HOUSE.
 THIS APPEARS TO BE HABITABLE SPACE (SHOWS WINDOWS,
 ROOF, FLOOR). SHOW THAT THIS AREA MEETS THE NFIP
 REQUIREMENTS (MINIMUM 7'6").
  
 FOURTH REVIEW, SEE FEMA TECHNICAL BULLETIN 11,
 CRAWLSPACE CONSTRUCTION. BOTTOM OF FLOOR JOISTS APPEARS
 TO BE BELOW 7'6" IN PORTIONS OF THE HOUSE. PLEASE
 REVISE PLAN AND/OR ELEVATION CERTIFICATE/SURVEY TO SHOW
 COMPLIANCE WITH NFIP REQUIREMENTS.
  
 SEE FEMA DOCUMENT REGARDING FLOOD OPENINGS. AN
 EVALUATION AND STATEMENT BY A DESIGN PROFESSIONAL IS
 REQUIRED. SEE P. 24
  
 3. THE FOLLOWING COMMENTS PERTAIN TO THE ELEVATION
 CERTIFICATE PROVIDED. PLEASE ALSO SEE ELEVATION
 CERTIFICATE INSTRUCTIONS,
 HTTP://WWW.FEMA.GOV/LIBRARY/VIEWRECORD.DO?ID=1383.
  
 A. SEE COMMENT #2 REGARDING FLOOD OPENINGS, A8 ON
 ELEVATION CERTIFICATE. PRIOR TO FINAL INSPECTION, A
 "FINISHED CONSTRUCTION" ELEVATION CERTIFICATE WHICH
 SHOWS COMPLIANCE WITH NFIP REQUIREMENTS IS REQUIRED.
  
 B. PROVISO, FINISHED CONSTRUCTION ELEVATION CERTIFICATE
 WILL BE REQUIRED PRIOR TO FINAL INSPECTION.
  
 C. ADDRESSED.
  
 D. ORIGINAL SIGNED AND SEALED DOCUMENTS REQUIRED, SEE
 ELEVATION CERTIFICATE INSTRUCTIONS (NEED SIGNATURE ON
 ELEVATION CERTIFICATE).
  
 E. N/A (SEE OTHER COMMENTS REGARDING FLOOR ELEVATION).
  
 4. PROVISO - SEPARATE PERMIT MECHANICAL.
  
  