| Plan Review Notes For Permit 10110499 |
| Permit Number |
10110499 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2010-11-19 11:04:18 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | | PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | | LIMITATION #7 TO MEET THE DESIGN PRESSURES REQUIRED BY | | | SEC. R301 OF 2007 FLORIDA RESIDENTIAL CODE. | | | | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. SEC. 108.3 CITY AMENDMENTS TO FBC 2007. VALUATION | | | WAS UPDATED. OWES $215.21. THIS INCLUDES THE UPDATED | | | PERMIT FEE VALUE AND THE BALANCE OWED AT TIME OF PERMIT | | | APPLICATION. | | | | | | 3- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|