| Notes |
| Date |
Text |
| 2010-11-30 09:54:39 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- APPROVED ASSEMBLY ON PAGE 8 SELECTED ON NOA | | | 07-0730.03 SUBMITTED CAN'T BE USED BECAUSE IT DOESN'T | | | MEET THE DESIGN PRESSURES FOR THIS BUILDING. ALSO, THIS | | | ASSEMBLY IS LIMITED BY GENERAL LIMITATION #9 WHICH | | | DOESN'T ALLOW NAIL ENHANCING. SEE GENERAL LIMITATION #9 | | | ON LAST PAGE OF NOA SUBMITTED. | | | SELECT ANOTHER ASSEMBLY THAT IS LIMITED BY GENERAL | | | LIMITATION #7 AND PROVIDE THE RESPECTIVE RAS 117 | | | CALCULATIONS FOR NAIL ENHANCING. | | | ***NOTE: THIS BUILDING IS LOCATED ON EXPOSURE "C". | | | | | | 2- ACCORDING TO MIAMI-DADE WEBSITE NOA 07-0730.03 | | | SUBMITTED WAS SUPERSEDED. NEED TO PROVIDE CURRENT NOA | | | 09-0820.11. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|