| Plan Review Notes For Permit 10090442 |
| Permit Number |
10090442 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2010-09-30 16:28:31 | BUILDING PROVISO: | | | 2007/09 FBC-B VERTICAL EXIT ENCLOSURES 1020 | | | | | | 1020.1.2 PENETRATIONS. PENETRATIONS INTO AND OPENINGS | | | THROUGH AN EXIT ENCLOSURE ARE PROHIBITED EXCEPT FOR | | | REQUIRED EXIT DOORS, EQUIPMENT AND DUCTWORK NECESSARY | | | FOR INDEPENDENT PRESSURIZATION, SPRINKLER PIPING, | | | STANDPIPES, ELECTRICAL RACEWAY FOR FIRE DEPARTMENT | | | COMMUNICATION SYSTEMS AND ELECTRICAL RACEWAY SERVING | | | THE EXIT ENCLOSURE AND TERMINATING AT A STEEL BOX NOT | | | EXCEEDING 16 SQUARE INCHES (0.010 M2). SUCH | | | PENETRATIONS SHALL BE PROTECTED IN ACCORDANCE WITH | | | SECTION 712. THERE SHALL BE NO PENETRATIONS OR | | | COMMUNICATION OPENINGS, WHETHER PROTECTED OR NOT, | | | BETWEEN ADJACENT EXIT ENCLOSURES. | | | | | | |
|