Plan Review Notes
Plan Review Notes For Permit 10090234
Permit Number 10090234
Review Stop B
Sequence Number 1
Notes
Date Text
2010-09-15 13:55:22BUILDING PLAN REVIEW
 PERMIT: 10090234
 ADD: 477 ROSEMARY AVE SUITE# 205/207/209/211/213/215)
 CONT: TBD
 CONTACT MIKE STELLINO
 TEL: (561)650-0900
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW: DENIED
  
 1) CONTRACTOR WILL NEED TO BE SIGNED ONTO THE PROJECT
 AND LICENSURE REVIEWED.
  
 2) PLANS WILL NEED TO BE REVIEWED BY CITY PLACE AND
 THEIR STAMP AFFIXED.
  
 3) PLANS WILL NEED TO BE REVIEWED BY PALM BEACH COUNTY
 IMPACT FEE OFFICE FOR ASSESSMENT. IT APPEARS THAT NONE
 OF THESE SPACES HAVE BEEN REVIEWED BY P B COUNTY
 FOR CHANGE OF OCCUPANCY. OUR RECORDS INDICATE:
 07060304 UNIT# 207 -EXPIRED NEVER ISSUED
 08080246 UNIT# 209 -EXPIRED NEVER ISSUED
 03110332 UNITS 213& 215, ISSUED BUT NO IMPACT FEE STAMP
 ON PLANS NOR COUNTY RECEIPT
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
 GYPSUM BOARDS IN SHOWERS & WATER CLOSETS
  
 2509.1 WET AREAS. SHOWERS AND PUBLIC TOLIET WALLS SHALL
 CONFORM TO SECTION 1210.2 AND 1210.3.
  
 2509.2 BASE FOR TILE. CEMENT, FIBER-CEMENT OR GLASS MAT
 GYPSUM BACKERS IN COMPLIANCE WITH
  
 ASTM C 1178-08 STANDARD SPECIFICATION
 FOR COATED GLASS MAT WATER-RESISTANT GYPSUM
  
 ASTM C 1288-99 STANDARD SPECIFICATION
 FOR DISCRETE NON- ASBESTOS FIBER-CEMENT INTERIOR
 SUBSTRATE SHEETS
  
 ASTM C 1325-08 STANDARD SPECIFICATION
 FOR NON-ASBESTOS FIBER-MAT REINFORCED CEMENTITIOUS
 BACKER UNITS
  
 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER
 RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE
 IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN
 SHOWER AREAS. WATER-RESISTANT GYPSUM BACKING BOARD
 SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET
 COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH
 GA-216 OR ASTM C 840 AND MANUFACTURER RECOMMENDATIONS.
 REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR
 WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC


Account Summary | Usage Policy | Privacy Policy