2010-10-01 15:11:37ROOFING:
  
 BUILDING PROVISO:
 1507.2.8 UNDERLAYMENT APPLICATION. FOR ROOF SLOPES FROM
 TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (17-PERCENT
 SLOPE) AND UP TO FOUR UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (33-PERCENT SLOPE), UNDERLAYMENT SHALL BE
 TWO LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A
 MINIMUM 19-INCH-WIDE (483 MM) STRIP OF UNDERLAYMENT
 FELT PARALLEL WITH AND STARTING AT THE EAVES, FASTENED
 SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE,
 APPLY 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT
 OVERLAPPING SUCCESSIVE SHEETS 19 INCHES (483 MM), BY
 FASTENED SUFFICIENTLY TO HOLD IN PLACE. DISTORTIONS IN
 THE UNDERLAYMENT SHALL NOT INTERFERE WITH THE ABILITY
 OF THE SHINGLES TO SEAL. FOR ROOF SLOPES OF FOUR UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE) OR
 GREATER, UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE
 FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE
 FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND
 LAPPED 2 INCHES (51 MM), FASTENED SUFFICIENTLY TO HOLD
 IN PLACE. DISTORTIONS IN THE UNDERLAYMENT SHALL NOT
 INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL.
  
 FL-10124-R1
 GAF
 ASPHALT SHINGLES