| 2010-10-12 15:41:41 | DENIED BY BUILDING |
| | |
| | 1) SPECIFY THE NAME AND LICENSE NUMBER OF THE PERSON |
| | RESPONSIBLE FOR THE DESIGN ON THE PLANS. IF PERSON IS |
| | LICENSED UNDER FS 471 OR 481, THEN APPROPRIATE SEALS |
| | AND SIGNATURES ARE REQUIRED. |
| | |
| | 2) PROVIDE A FLOOR PLAN SHOWING THE EXISTING FIRST |
| | FLOOR AND A SEPARATE FLOOR PLAN SHOWING THE PROPOSED |
| | CHANGES. |
| | |
| | 3) PROVIDE SQUARE FEET AREA OF EXISTING FIRST FLOOR |
| | LIVING SPACE AND GARAGE AREA AND THE TOTAL AMOUNT |
| | LIVING SPACE AFTER CHANGES. |
| | |
| | 4) PROVIDE DETAILS FOR THE EXTERIOR WALLS AT THE NEW |
| | WASHER/DRYER ENCLOSURE AND THE IN-FILL AT THE EXISTING |
| | GARAGE DOOR OPENING. SPECIFY FRAMING MATERIAL, ANCHORS, |
| | STRAPS, INSULATION, INTERIOR FINISH AND EXTERIOR |
| | FINISH. |
| | |
| | 5) PROVIDE DETAILS OF THE EXTERIOR EGRESS STAIRS THAT |
| | ARE BEING REPLACED. SHOW COMPLIANCE WITH FBC R311.5 |
| | STAIRWAYS, R312 GUARDS AND R301.5 LIVE LOAD. |
| | |
| | 6) THE CONDITIONED FIRST FLOOR AREA ON THE ENERGY |
| | CALCULATION FORM IS 336 SQFT AND ON THE PLANS IT IS 510 |
| | SQFT. PLEASE CLARIFY. |
| | |
| | 7) THE PLANS SPECIFY THE OCCUPANCY AS R-2. BECAUSE THIS |
| | IS A TWO UNIT RESIDENCE, IT IS CONSIDERED AN R-3 |
| | OCCUPANCY. PLEASE REVISE PLANS. |
| | |
| | 8) SUBMIT TWO COPIES OF CURRENT PRODUCT APPROVALS FOR |
| | THE IMPACT RATED HORIZONTAL SLIDING WINDOW IN BEDROOM |
| | #2 AND THE EXTERIOR DOUBLE DOORS AT THE NEW LAUNDRY |
| | ROOM AS REQUIRED BY DCA RULE 9B-72. |
| | |
| | 9) SUBMIT TWO COPIES OF CURRENT PRODUCT APPROVALS FOR |
| | THE IMPACT RATED SINGLE HUNG WINDOWS. THE ONES THAT |
| | WERE SUBMITTED HAVE BEEN SUPERSEDED BY NOA NO. |
| | 09-0916.05 AND ARE NO LONGER CURRENT. |
| | |
| | 10) BECAUSE THE EXISTING GARAGE IS BEING CONVERTED TO |
| | LIVING SPACE, THE PLANS WILL NEED AN IMPACT FEE REVIEW |
| | BY PALM BEACH COUNTY. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | [email protected] |