2011-05-19 13:57:30PLUMBING PLAN REVIEW
 PERMIT: 10090080
 ADD: 926 SUNSET RD
 CONT: O/B MARIA GEORGE
 TEL: (561)718-4600
 FL BLD CODE= 2007 FLORIDA BUILDING CODE- W/ 2009 FBC
 SUPPLEMENTS
 MAY 19/ 2011
  
 PLUMBING PLAN REVIEW
 PLUMBING PROVISO:
  
  
  
  
 1) A REVISION WILL BE REQUIRED FOR THE PLUMBING
 DRAINAGE FLOOR PLAN & SANITARY ISOMETRIC. THE CURRENT
 LAYOUT INDICATES THE KITCHEN AND WASHING MACHINE DRAINS
 TYING INTO A WET VENT (BATHROOM GROUP) A PLUMBING CODE
 VIOLATION PER (FBC-P909.1). THE PREVIOUS PLAN REVIEW
 REQUESTED A VIDEO OF THE SANITARY AND ISOMETRIC OF WHAT
 WAS INSTALLED WITHOUT PERMIT. THE ISOMETRIC WAS NOT
 DELIVERED BUT THE VIDEO WAS PRESENTED AND IT IS EVIDENT
 IN THE VIDEO THE PIPES ARE BACK PITCHED RETAINING WATER
 IN THE PIPES CREATING A SECOND CODE ISSUE (FBC-P
 704.1/TABLE 704.1). IT APPEARS THAT THE INSTALLATION
 MAY HAVE BEEN INSTALLED BY AN O/B, AND WE WOULD SUGGEST
 YOU CONTACT A PLUMBING CONTRACTOR TO CORRECT THE CODE
 VIOLATIONS WITH NEW SANITARY OR PORTION THERE OF AND
 REVISION. WE WOULD BE GLAD TO MEET WITH WHOEVER YOU
 WOULD LIKE BEFORE WORK BEGINS. NOTE THIS REVISION WOULD
 NEED TO BE SEALED BY THE DESIGNER OF RECORD.
  
  
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
2011-04-28 10:47:49WAITING FOR OWNER TO BRING IN VIDEO OF SANITARY SEWER
 FOR PLUMBING REVIEW. JW