| Plan Review Notes For Permit 10080780 |
| Permit Number |
10080780 |
|
| Review Stop |
B |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2010-08-31 08:58:23 | BUILDING REVIEW FOURTH CHECKLIST. | | | | | | 1- ROOF OVER USING GAF MATERIALS CAN'T BE DONE ON THIS | | | BUILDING. THERE ARE TWO NOTICE OF ACCEPTANCES FOR GAF | | | RECOVERY DECKS. THEY ARE NOA 08-0221.08 AND 08-0221.11. | | | NONE OF THE APPROVED ASSEMBLIES LISTED ON THESE NOA'S | | | CAN'T BE USED IN THIS BUILDING BECAUSE THEY ARE LIMITED | | | BY GENERAL LIMITATION #9. THIS LIMITATION DOESN'T ALLOW | | | NAIL ENHANCING TO INCREASE THE DESIGN PRESSURES OF THE | | | ASSEMBLY. SEE GENERAL LIMITATION #9 ON LAST PAGE OF | | | NOA'S. THE DESIGN PRESSURES LISTED ON THE APPROVED | | | ASSEMBLIES ARE TOO LOW TO MEET THE DESIGN PRESSURES | | | REQUIRED BY SEC. R301 OF 2007 FLORIDA RESIDENTIAL CODE. | | | THEREFORE, PROPOSED INSTALLATION IS NOT ALLOWED. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|